Log in to see the plans as drawnrecreation or community activity on the activity on the same site and do not
same site. exceed a combined total use area of
150m² and sell only nonalcoholic
drinks and light meals.
AO13.2
Food and drink outlets within an
existing sporting club or community
use, including indoor and outdoor
dining space, does not exceed a gross
floor area of 150m²
Healthcare Not applicable
PO14 No acceptable outcome provided
Hospital and healthcare services
colocate on and near to existing
hospital or health care services sites to
complement existing services and
create health hubs where possible.
Noosa Airport Not applicable
PO15 No acceptable outcome provided
The amenity of sensitive land uses
surrounding Noosa Airport is not
adversely affected by the operations
of the Noosa airport.
PO16 Not applicable
The existing and future operational No acceptable outcome provided
requirements of the Noosa Airport are
protected from inappropriate or
incompatible development.
Built Form
Performance outcomes Acceptable outcomes Comment
Built form
Height
PO17 AO17.1 Complies
Buildings and other structures: Within urban boundaries buildings
(a) are low rise and have a visual and other structures are no more
bulk and architectural scale than 8 metres in building height.
consistent with the character
of the area; AO17.2 Not applicable
Outside of urban boundaries
(b) do not visually buildings and structures are no
dominate the street more than 8 metres in building
and surrounding height, providing that they may be
up to 9 metres where the pitched
spaces;
roof but no other part of the
(c) preserve the amenity of building or structure exceeds 8
metres.
surrounding development
including privacy, views and
AO17.3 Complies
access to sunlight to Where excavation is required, the
residential dwellings; maximum portion of the exposed
external façade of the building
(d) respect the scale of the cannot exceed 8 metres in building
surrounding vegetation, height.
maintaining a vegetated Editor's note—refer to figure AP313A
skyline; and
Editor’s Note—utility installations and
(e) have a maximum building telecommunication facilities may
height of two storeys. require a greater height which would be
assessed on a case bycase basis but is
not likely to exceed 15 metres within
urban boundaries or 25 metres outside
urban boundaries.
Site cover, gross floor area and
building bulk AO18.1 Complies
PO18 Individual buildings do not exceed a
Buildings and other structures: gross floor area of 1,000m².