                                 AO14.4 If in the Rural zone or Not applicable
                                 Rural    Residential zone,     the The site is in the High Density
                                 driveway and cross-over is located Residential zone.
                                 to provide minimum safe sight
                                 distances in accordance with
                                 Austroads.


                                 Editor's Note - An operational works
                                 application is required for a second
                                 driveway.

Bushfire Hazard Management           AO15 Within a bushfire hazard Not applicable
PO15 Where located in a Bushfire area where there is no reticulated The site can be connected to
Hazard Area as shown on the water supply, the premises has:              reticulated water.
Bushfire Hazard Overlay Map in 1.​            an     accessible     dam,
Schedule 2 and not in a water swimming pool or water tank
service area, an adequate, reliable, available for firefighting purposes
safely located and freely accessible with an onsite water volume of not
water supply is provided for fire less than 5,000 litres; and
fighting purposes, which is in 2.​            a water supply outlet pipe
addition to day to day water supply. 50 millimetres in diameter and
                                 fitted with a standard fire brigade
                                 fitting connected to the water
                                 supply (other than where the water
                                 supply is in a swimming pool or
                                 dam).


                                 Editor’s Note — Water supply
                                 capacity for firefighting purposes is
                                 in addition to water supply capacity
                                 for household use.

Flood Hazards                      AO16.1 Where the development is Not applicable
PO16 Development is designed located in the Flood Hazard Area as The site is not mapped in the
and sited to ensure risk to people shown on Flood Hazard Overlay Flood Hazard Area.
and property from flooding is Map in Schedule 2, the finished
avoided or minimised.              floor level of habitable rooms is at
                                   least 300 millimetres above the
                                   Defined flood event (DFE).


                                 OR


                                 AO16.2 Where the DFE has not Not applicable
                                 been modelled for the area, the
                                 finished floor level of habitable
                                 rooms is at least 500 millimetres
                                 above the highest recorded flood.


                                 Editor's Note—The QDC mandatory
                                 provisions MP3.5 also apply to the



                                                                                                24

Used in these records

About this file

File size
7.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Town Planning Assessment Report.pdf · 7.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.