Skip to the record
Every meeting, every word.

Council archive · source document

Collated Planning Report · MCU14/0077

Attached to the e-mail MCU14/0077 & OPW14/0324 Industrial business Type 1 & Retail business Type 4.

of 118

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Original PDF page 111, section 1. The text section number identifies this passage in the reader.

a) appropriate siting and access;
b) the provision of lighting; and
c) restricting access to the general public
by making the area clearly identifiable as
private space (eg. through landscaping,
change of paving material or fencing,
rather than locking the area.

Water     management     for    waste         S7.1 The waste storage area —                             Complies.
storage areas                                 a) is bunded and graded so that washwater and bin
O7 Waste storage areas are designed to        leakage are drained to the sewer or an on-site effluent   As shown on the Engineering Plans contained within Appendix D of this
contain and appropriately dispose of          disposal system via a gully within the storage area;      report the proposed waste storage area is to be bunded to prevent
leakage from bins and wastewater from         b) has a bund wall with a maximum height of 100mm;        stormwater coming in contact with any contaminants. Furthermore,
bin washing.                                  c) is serviced by a conveniently located hosecock and     any liquid which is located within the waste storage area will be
                                              backflow prevention device, and connected to a water      captured and drain via a pipe to Council’s reticulated sewerage system.
                                              supply; and
                                              d) is roofed or otherwise covered if the storage area
                                              is—
                                                              2
                                              i) more than 1m ; or
                                              ii) storing wet waste; or
                                              iii) storing other waste with a high potential to cause
                                              pollution if washed or leaked from the bins, including
                                              waste oil or putrescibles.

Used in these records

About this file

File size
8.6 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Collated Planning Report.pdf · 8.6 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.