Council archive · source document
Collated Planning Report · MCU14/0077
Attached to the e-mail MCU14/0077 & OPW14/0324 Industrial business Type 1 & Retail business Type 4.
Original PDF page 98, section 1. The text section number identifies this passage in the reader.
Application for a Development Permit for Material Change of Use to establish an Industrial Business, Type 1 Warehouse and Retail Business, Type 4 Showroom (Trade Related Showroom, Plumbing Supplies) and Operational Works (Stormwater Drainage, Landscaping, Car Parking and Access Driveway), on land identified as Lot 10 on SP230643, situated at 10/100 Rene Street, Noosaville Qld 4566 EXISTING SERVICES CODE Specific Outcomes Probable Solutions How does the proposal comply with the Overall Outcome/s or Specific Outcome/s? Setbacks and easements Complies. O1 Development near a sewer, water main, S1.1 The footing of any structure or building is stormwater drain, overland flow path or located clear of the zone of influence but no closer No building or structure associated with the proposed development associated structure does not— than 1.5m (measured horizontally) from will be located closer than 1.5m from Council’s infrastructure. a) adversely affect the function of the infrastructure including sewers, water mains and service; stormwater structures; The finished surface level of the subject site will maintain a minimum b) place an additional load on the service; of 600mm cover over the underground infrastructure. and AND c) unduly increase future maintenance costs. Any manhole or inspection point, which is disturbed or altered during S1.2 No building or structure overhangs the zone of construction will be replaced to match the new surface level. influence; For further details please refer to Appendix D of this report, which AND contains Engineering Plans that show the location of existing infrastructure as well as the finished surface level of the proposed S1.3 Finished surface levels maintain a minimum of development. 600mm of cover, but no greater than 3m of cover to the underground infrastructure; AND S1.4 If the existing surface level is altered, surface level services including manholes and inspection points are altered to match the new surface level; AND S1.5 Alterations are constructed in accordance withPSP6 –Engineering Design Standards — Water and Sewerage and Section 4 of PSP5 –Engineering Design Standards – Roads, Drainage and Earthworks; OR
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Collated Planning Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 8.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.