Info Request MCU16/0153
MCU16/0153 Issue – Noise monitoring of IGA loading dock The acoustic report makes some assumptions regarding the number, timing and noise levels of trucks that access the IGA loading dock but does not verify the assumptions by attended observations or by noise monitoring on the subject site at representative façade locations near the loading dock. The acoustic report assumes that there will only be a limited number of delivery vehicles that will access the loading dock or shopping village and only after 7am. Information Required 13. Unattended noise monitoring shall be conducted at a location on the development site that has a clear view of the loading dock and car park at a height representative of the façade of the first floor motel units for a minimum period of one week. The noise logger is to have one-third octave spectral data and audio recording capabilities so that the source of noticeable dominant events may be confirmed and the contribution of extraneous noise sources may be identified. The noise logger is to record levels continuously with a sampling period no greater than 1 second and preferably one-eighth of a second (FAST response). Of particular interest are the times, durations and frequency spectra of trucks accessing the loading dock for deliveries or waste collection prior to 7am daily and vehicle and patron noise after 10pm. Issue – Noise monitoring of IGA roof plant The air-conditioning and refrigeration plant for the IGA are mounted on the roof of the IGA store. The noise emissions are stated in the acoustic report to have been previously measured by ASK on the roof of the IGA store. Plant noise levels but no acoustic spectral information is provided in the acoustic report. The acoustic report does not state whether the propagated noise at the receptor locations is likely to be predominantly low frequency, or whether it has low frequency tonal components. 14. A SoundPLAN noise model of the IGA roof-top mechanical plant shall be prepared based upon octave or one-third octave spectral noise data for the roof-top mechanical plant. Noise levels shall be predicted which show the predicted noise contours (1m grid) at the motel (first and second storeys), the four nearest attached houses (first floor) and the nearest linea unit (first floor), with and without the proposed partial enclosure around the mechanical plant. The noise contours shall demonstrate that the proposed partial enclosure barrier (1m height above the height of the mechanical plant) around the sides of the mechanical plant deck provides sufficient noise mitigation for all affected receptors to achieve compliance with the external noise limits. 15. Noise calculations shall be conducted which predict the internal noise levels in the motel unit (first and second levels), houses and linea units (upper levels) to confirm compliance with the internal noise criteria in each type of habitable space. Calculations should demonstrate the transmission loss of the building envelope of all affected habitable spaces provides sufficient noise attenuation to achieve compliance with the internal noise limits for IGA mechanical plant noise emissions, including adverse noise character adjustments. The building envelope noise intrusion calculations should be conducted in accordance with the method of AS3671 based upon octave spectral levels and the building envelope construction Page 4 of 13 Document Set ID: 20272939 Version: 3, Version Date: 10/02/2017
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.