Appendix F - Bushfire Hazard Assessment & Management Plan

of 36

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
Bushfire Hazard Assessment & Management Plan v1                                  NCES REF: J000669
Lot 2 on RP131369 – 108 Black Mountain Range Road, Black Mountain



    ·    No woody mulch is used within 2m of buildings;
    ·    No trees or shrubs are retained within 6m of the buildings;
    ·    Beyond 6m, any trees desired to be retained are to be continuously defoliated below
         < 4m height above ground level and no limbs are to extend to within 6m of the roof line
         of the buildings. All pruning should be undertaken in accordance with AS 4373 Pruning
         of amenity trees;
    ·    Future landscaping works/plantings maximise the use of locally indigenous, low
         flammability species and or low-density plantings of suitable open forest /woodland
         species with low bark shedding characteristics. Landholders should consult their local
         native plant nursery for suitable species selection.
The low threat conditions within Lot 2 are to be maintained by the respective individual
landholder/s and or occupants in perpetuity.

5.7 General Property Maintenance
The undertaking of an appropriate level of property maintenance throughout the year, and in
particular prior to the fire season, can significantly reduce the severity of fire impact upon a
site. Queensland Fire and Emergency Services recommend the following general actions be
undertaken to prepare for the fire season:
Structure
    ·    Clear leaves, twigs, bark and other debris from the roof and gutters.
    ·    Purchase and test the effectiveness of gutter plugs.
    ·    Enclose open areas under decks and floors.
    ·    Install fine steel wire mesh screens on all windows, doors, vents and weep holes.
    ·    Point LPG cylinder relief valves away from the house.
    ·    Conduct maintenance checks on pumps, generators and water systems.
    ·    Seal all gaps in external roof and wall cladding.
Access
    ·    Display a prominent house or lot number, in case it is required in an emergency.
    ·    Ensure there is adequate access to your property for fire trucks - 4 metres wide by 4
         metres high, with a turn-around area.
Vegetation
    ·    Reduce vegetation loads along the access path.
    ·    Mow your grass regularly.
    ·    Remove excess ground fuels and combustible material (long dry grass, dead leaves
         and branches).
    ·    Trim low-lying branches two metres from the ground surrounding your home.
Note the above recommendations are that of QFES and are offered herein for advisory
purposes. They have not been set as recommendations for certification purposes.




© 2021                                                      23
Log in to download the original file

Appendix F - Bushfire Hazard Assessment & Management Plan.pdf · 3.8 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.