PLANNING & ENVIRONMENT COMMITTEE MEETING AGENDA                            10 DECEMBER 2019


    93.   High-flow bypass / first-flush capture design capacity must be designed to meet the
          defined discharge criteria during a storm up to the 3 month ARI-6 minute design
          rainfall event without surcharging or backing up the drainage system.
          Submit Certification
    94.   Prior to the commencement of the use certification shall be provided to Council
          demonstrating that the system has been installed in accordance with the above.
          Noise
    95.   Mechanical plant and equipment, a/c units, motors, refrigeration equipment,
          compressors, pumps etc. on site must be located within the building or suitably
          provided with noise reduction measures and located to prevent a noise nuisance
          beyond the boundary of the site and to not exceed the levels specified in Table 1.
          Table 1

          NOISE LIMITS AT A SENSITIVE RECEPTOR

          PERIOD           Noise level at noise sensitive place measured as the adjusted
                           maximum sound pressure level (Lamax, adj,T)

          7am – 6pm        Background noise level (LAbg,T) plus 5 dB(A)

          6pm – 10pm       Background noise level plus 5 dB(A)

          10pm – 7am       Inaudible

          NOISE LEVELS AT COMMERCIAL PLACE

          PERIOD           Noise level at a commercial place measured as the adjusted
                           maximum sound pressure level (Lamax, adj,T)

          7am – 6pm        Background noise level (LAbg,T) plus 10 dB(A)

          6pm – 10pm       Background noise level plus10 dB(A)

          10pm – 7am       Background noise level plus 8 dB(A)

    96.   When requested by Council, a Noise Impact Assessment Report (NIAR) showing
          monitoring and recording of noise levels must be undertaken to investigate any
          complaint (other than a frivolous or vexatious complaint) caused by noise emissions
          from operations at the premises.
    97.   Such monitoring must be undertaken within a reasonable and practicable timeframe
          nominated by Council and be performed by a suitably qualified person in accordance
          with accepted guidelines and standards. The report is to be submitted to Council
          detailing the results of such monitoring and recommendations for any measures to
          achieve compliance with limits outlined in Table 1 of this Decision Notice.
          For the purpose of measuring and certifying relevant noise conditions and reporting
          (e.g. mechanical plant and equipment, a/c units, motors, refrigeration equipment,
          compressors, pumps, rooftop plant and equipment. etc) a suitably qualified person is
          either:
          a.   a Registered Professional Engineer of Queensland, or
          b.   an environmental consultant with a minimum of three (3) years current
               experience in the field of acoustics.



                                                                                Page 35 of 84
Log in to download the original file

2019-12-10 Planning & Environment Committee Agenda(PDF, 6MB).pdf · 6.2 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.