Project Handover & Maintenance Manual – Fytogreen Australia Pty Ltd




(j) Drainage, Irrigation and Fertigation Individual Components Inspection and
    Maintenance Items:
                                                                                                              Necessary Action
      Area of                                Inspection      Inspection Procedure as applicable            (Recommend contact
                       Inspection Item
     Attention                               Frequency         to detailed/cursory inspections           Fytogreen Australia Pty
                                                                                                                      Ltd)
                                                            Check power / operation and run self             Repair / Replace as
                     Galcon GSI Irrigation                              diagnostic test                   required if faulty; Call the
                          Controller                        (Refer to Fytogreen Irrigation Users         Manufacturer for Technical
                                                                             Guide)                                support)
                        Hunter Master                           Check that the solenoid valve is             Repair / Replace as
                     Solenoid valve with                        regulating flow, (Listen for clicks             required faulty
                         Flow Control                             sounding) open on actuation                 valve/component
                                                                                                          Repair / Replace / clean
                                                              Checks leaking seals, suction tube
                                                                                                          as required faulty / dirty
                                                            connections (no leaks) and that filter are
                     Dosatron Compact D                                                                      valves/components
                                                             clean. Check bypass valve for correct
                      Fertigation injector   Inspections                                                       Call “Dosatron”
                                                             operation (Listen for clicking noise of
                                              required 6                                                 Manufacturer for Technical
                                                                    pump during operation)
                                             times a year                                                          support)
                                                            Check static / operational pressuring
                      “Caleffi” Pressure                                                                  Inspect / clean / replace as
    Automated                                                  on valve (should read 350kpa –
                     Reducing valve with                                                                       per manufactures
    Irrigation &                                            (Refer to Fytogreen Irrigation Users
                       Pressure Gauge                                                                             Instructions
  Fertigation unit                                                           Guide)
    individual         MV80 Solenoid                            Check operation and run self             Inspect / replace with equal if
   components          valves for each                           diagnostic test via Irrigation            damaged or faulty (Refer
                        irrigation zone                                    Controller                         specification sheet)
                                                             Check for correct operation during          Inspect / replace with generic
                      Dual check valve                       and after normal operation (should           valve if damaged or faulty
                                                                          be no leaks)                    (refer general spec sheet)

                          Ball valves                                      As above                                As above

                          Y strainer                          Unscrew, check port, check filter,
                                                                                                                   As above
                                                              should appear in clean condition

                     Swing check valves                                    As above                                As above

                                                             Check for leaks, correct readings /         Inspect / replace as required
                       Water meter with                        output by performing a general               damaged or faulty units
                         pulse output                        operations test (Refer to Fytogreen          (Call BES - Manufacturer
                                                                    Irrigation Users Guide)                for Technical support)




                     Project Handover & Maintenance Manual

Used in these records

About this file

File size
301 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Green wall Handover Manual.2.pdf · 301 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.