o Excavation is not permitted within 0.6m of a sewerage main. Any excavation
between 0.6m-1.0m to be had dug backhoe or vacuum excavated and
annotated on drawings as such. Bored piers are not permitted within 1.0m of
sewerage mains.
o The engineering detail must demonstrate that no load will be transmitted to
infrastructure within the zone of influence or angle of repose. A form 15 from
a RPEQ must also be submitted with the engineering design detail.
o Construction is not permitted within 1.5m of a maintenance structure with an
infinite vertical clearance above.
• Please note that a Service Advice Notice does not include a detailed assessment of
any related documents (including drawings and technical reports).
If you have any queries about the advice please contact Unitywater at
[email protected] or by phone on 1300 086 489.
Yours sincerely
Noel Killip
Team Leader Connections Approvals
Development Services
Unitywater advises that from 1 July 2021, all eligible connection applications to
Unitywater will need to be made under Unitywater’s Accreditation and Certification
System.
Page 3 of 3
Unitywater is a statutory authority that provides water and Unitywater has certification to:
OH&S AS/NZS 4801:2001 Reg No 500000079
sewerage services for the Moreton Bay, Sunshine Coast and Environmental ISO 14001:2015 Reg No 500000079
Noosa Council areas. Quality ISO 9001:2015 Reg No 500000079
Food Safety ISO 22000:2018 Reg No 500000079
Revision No: 3 Effective Date: 14/11/2019 Next Review Date: 14/11/2021
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.