Council archive · source document

house 4 and Site Plan · MCU16/0117.01

Attached to the e-mail Change to DA - MCU16-0117.01.msg.

of 12

Check the original when the exact wording matters.

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
                                                                                BOUNDARY LINE
                                                                                                                                      BOUNDARY LINE
                                                    FIRST FLOOR CEILING




          3000
                 CEILING HEIGHT



    370
                                                    FIRST FLOOR PLAN EXISTING

                                                    GROUND FLOOR CEILING




          2400
                          PROPOSED CEILING HEIGHT
                                                    GROUND FLOOR PLAN


                                                                                                FT   FT   FT   FT   FT

                                                                                                                                                      STEEL POST. REFER TO ENGINEER
                                                                                                                                                                     SPECIFICATIONS


                                                                                                                             CONCRETE FOOTING WITH STEEL POST
                                                          GALVANIZES STEEL FRAMED HWD
                                                                                                                             DESIGN TO STRUCTURAL ENGINEERS SPECIFICATIONS
                                                          TIMBER STAIR WITH BALUSTRADE.



                                                                                                                             TIMBER FLOOR FRAMING. REFER TO
                                                                                                                               FRAMING PLAN AND STRUCTURAL
                                                                                                                                   ENGINEERS SPECIFICATIONS




          SOUTH SECTIONAL ELEVATION
6         SCALE 1:100 @ A3




                                                                                                                    PROPOSED SITE PLAN FOR RESIDENCES ON
                                                                                                                                                                                      SOUTH SECTIONAL ELEVATION
                                                                                                                    11 OPAL STREET COOROY