CASTAWAYS BEACH
commencement of any works. These
P1 - RE-ISSUED FOR REVIEW
conjunction with Engineers Drawings
Verify all dimensions on site prior to
30 NOOSA DUNES,
Issue No.
PROPOSED FIRST
building designer licence 1016347
ADDITION OF LIFT
2317
Job No:
drawings remain the property of
07 54473255
07 54473299
standard Bldg By-law 1975 & as
as shown @A3 2023
WD.204 P1
drawings are not to be used for
scaling. Copyright for design &
Construction to comply with all
Date
relevant SAA & BCA Codes &
This drawing is to be read in
inf [email protected]
www.ct-design.com.au
noosa heads qld 4567
FLOOR PLAN
noosaville qld 4566
PROPOSED
HUDDART
46 mary street
Drawing Title
po box 613
14.12.2023
Drawing No.
the authors.
telephone
& Reports.
facsimile
amended.
Drawn By
Location
suite 2
Project
Client
Scale
SC
1:100
new window to match existing Ensuite 1 window
new wall opening to lift entry 1290w x 2300h
new lift, installed by specialist contractor,
new rendered blockwork lift shaft, finish
new wall infill, timber framed, internal &
refer to manufacturers specifications
to match existing Ensuite 1 awning
external finishes to match existing
new location of existing downpipe
new location of existing downpipe
new aluminium awning (over)
to match existing
2.0M SETBACK
PROPOSED FIRST FLOOR PLAN
3.0M SETBACK
BEDROOM 1
ENSUITE 1
REV DETAILS DRAWN CHECKED DATE
A ISSUED FOR APPROVAL PRAJWAL Y 08-11-2023
BUILDERS INFORMATION
DECK
timber
PHOENIX - STANDARD
existing
existing
LIFT SHAFT CONSTRUCTION
timber
SLAB / LIFT WELL
existing
HUDDART RESIDENCE
tile
1425
INTERNAL CERTIFICATION OF THE LIFT SLAB BY AN APPROVED ENGINEER.
MINIMUM CLEARANCE
ANY PIT SET DOWN SHOULD BE PROTECTED AGAINST ANY INGRESS OF
K
WATER.
1375 INDEPENDENT
AC
LIFT SHAFT LIFT WELL ENCLOSURE
BY OTHERS THE LIFT SLAB TO BE KEPT CLEAR OF RUBBISH AND WATER.
(PARENT STRUCTURE)
TB
THE LIFT PIT SLAB MUST BE LEVEL ACROSS ALL FOUR CONERS.
THE LIFT PIT MUST BE WITHIN 5MM OF WHAT HAS BEEN SPECIFIED.
(MEASUREMENT TAKEN FROM THE HIGHEST POINT OF THE LIFT SLAB)
SE
THE BUILDER MUST PROVIDE A CLEAR OPENING AT EACH LEVEL. NO
STUD OR BLOCK WALLS ARE TO BE CONSTRUCTED AT THE ENTIRE
M
FRONT FACE OF THE LANDINGS UNTIL AFTER THE LIFT IS IN PLACE AND
SECURED.
3.0
SHOULD ANY PHONE OR ELECTRICAL WIRING BE RUN WITHIN THE LIFT
SLAB / LIFT WELL
WELL IT MUST BE ENCLOSED IN CONDUIT AND SECURED AWAY FROM
1540
MOVING PARTS OF THE LIFT.
INTERNAL
MINIMUM CLEARANCE
LIFT WELL THE LIFT WELL SHALL HAVE NO SERVICES SUCH AS WATER PIPES,
2500 AIR-CONDITIONING OR VACCUM DUCTS RUN WITHIN IT.
2300
TOP OF SHAFT
LIFT WELL
MINIMUM 1490 THE LIFT WELL SHOULD BE PLUMB FROM THE TOP TO THE BOTTOM
OPENING
LIFT SHAFT WITH A MINIMUM CLEARANCE OF 25MM AT ALL POINTS TO THE LIFT
DRESSING
SHAFT.
timber
existing
1,600 200
200
TOP OF SHAFT
DP
DP
T1
2990
FFL - FFL
1,540
LIFT
2300
LIFT WELL
new
OPENING
KITCHEN
DP
timber
existing
CLIENT APPROVAL
PIT
80
SIDE SECTION GROUND FLOOR FIRST FLOOR
SIGNATURE
/ /
aussi el ft s
LIFT SHAFT/ WELL 1290
1,290 SCALE: A3 DRAWN PRAJWAL Y 08-11-2023
TYPICAL LIFT WELL DIMENSIONS: MM (UNLESS SPECIFIED) CHECKED 08-11-2023
OPENING CLIENT NAME DRAWING NUMBER REV
awning roof
HUDDART RESIDENCE 882251023-A A
SHEET 4 OF 5
existing
COPYRIGHT 2021 BY AUSSIE LIFTS PTY LTD. 12 ACHIEVEMENT CRES. ACACIA RIDGE. QLD 4110. TEL: (07) 3274 4211. THIS DRAWING REMAINS THE PROPERTY OF AUSSIE LIFTS & NO PART SHALL BE COPIED OR USED WITHOUT THE PERMISSION OF THE AFORMENTIONED COMPANY
below
DINING
timber
existing
SFL 13.700
timber decking
UP
STAIRS
timber
DECK
existing
UP
LIVING
timber