Council archive · source document
Plans · 132005.307.01
Plans and drawings: the text below has words only, no drawings.
suite 2
46 mary street
RL 16.400 LIVING CEILING
noosaville qld 4566
po box 613
existing downpipe to be relocated noosa heads qld 4567
LIVING/DINE
2,700
telephone 07 54473255
facsimile 07 54473299
existing roof over Drying Yard to be removed
RL 13.700 FIRST FLOOR inf [email protected]
existing downpipe to be relocated
www.ct-design.com.au
existing external laundry door to be removed,
prepare for new wall infill building designer licence 1016347
3,000
existing downpipe to be removed
ENTRY DRYING GARAGE This drawing is to be read in
existing structural post to be cut down
conjunction with Engineers Drawings
to height of existing Drying Yard screen & Reports.
RL 10.700 GROUND FLOOR existing aluminium screen shown hidden (dashed) for clarity
Construction to comply with all
RL 10.600 DRYING YARD relevant SAA & BCA Codes &
100
confirm existing drying yard slab has been built at RL 10.600. standard Bldg By-law 1975 & as
80mm below Entry FFL required for proposed lift shaft. amended.
Note! builder to confirm that existing slab will accomodate lift above Verify all dimensions on site prior to
commencement of any works. These
drawings are not to be used for
scaling. Copyright for design &
drawings remain the property of
the authors.
EXISTING WEST ELEVATION 1:100
RL 16.400 LIVING CEILING
new roof over lift shaft - existing roof sheeting, rafters,
gutter & fascia to be extended to accomodate
new blockwork lift shaft, finish to match existing
LIVING/DINE LIFT
2,700
- rendered with expressed joint every 400mm
new location of existing downpipe
P1 - RE-ISSUED FOR REVIEW
new location of existing downpipe 14.12.2023
RL 13.700 FIRST FLOOR Project
existing structural post cut back to height
PROPOSED
of existing p/c aluminium screen ADDITION OF LIFT
proposed location of new lift machine cabinet, Location
3,000
ENTRY DRYING GARAGE
installed by specialist contractor, refer to manufacturers specifications 30 NOOSA DUNES,
CASTAWAYS BEACH
existing aluminium screen shown hidden (dashed) for clarity Client
RL 10.700 GROUND FLOOR
RL 10.600 DRYING YARD
HUDDART
100
Drawing Title
WEST ELEVATIONS
Scale Date
as shown @A3 2023
Drawn By Job No:
SC 2317
PROPOSED WEST ELEVATION 1:100 Drawing No. Issue No.
WD.501 P1