Council archive · source document
SUPERSEDED Minor Change Existing Approval MCU21/0117 01 & OPPW21/0199.01 · MCU21/0117.01
The following plans require amendment.
Plan No. Rev. Plan/Document Name Date
23098/SK10 G Concept Site Levels and Drainage Plan 14/05/2024
1. The drawing is marked as conceptual and includes a note
Amendments
advising the drawing is not to be used for construction. Provide
an amended plan that is suitable for Operational Works
Construction for Council approval prior to the prestart meeting.
2. Prior to the prestart meeting, provide an amended plan to Council
for approval that includes the frontage works required in
accordance with the MCU Conditions.
3. Prior to the prestart meeting, provide updated engineering plans
which specifically address the following:
a. A piped solution is proposed for Lot 1 SP153798. Due to the
proposed surface levels of the development driveway, when
events exceed the 2%AEP, or when blockage of the pipe inlet
occurs, flooding/ponding on the upstream lot will occur.
Revise the design to ensure that no ponding/flooding on the
upstream lot will occur in the 1%AEP event based on design
blockage allowance for any pipe system, consistent with
QUDM.
b. Provide cross and long sections and hydrologic and hydraulic
calculations for the swales proposed in the following
locations:
i. On the eastern boundary of the development site to
convey flows from outlet 2/1 to the LPD
ii. From the driveway low-point to the bioretention basin
iii. On the northern and eastern boundaries of Lot 1
SP153798 to convey runoff from the external
catchment to inlet 1/1
c. Provide ILs for the structures on the proposed stormwater
line and confirm what type of structure is 1/1 (headwall or
field inlet)
CURRENCY PERIOD
49. The Currency Period for this development approval lapses if the development has not
substantially started by 10 November 2027, unless an application to extend the currency
period is approved by Council.
SITE SPECIFIC CONDITIONS
50. Deleted.
PRIOR TO COMMENCEMENT OF WORKS
Engineering
51. All necessary approvals from external service providers (e.g. Unitywater) and external parties
on which the development works are proposed have been obtained and a copy supplied to
Council.
Page 9 of 31
Document Set ID: 23112081
Version: 5, Version Date: 17/07/2024
See the original
The page text is free to read. Viewing or downloading an original file needs an account.