Council archive · source document
SUPERSEDED Decision Notice - 010.2007.00000616.001 [As Published] · 132007.616
NOOSA COUNCIL IDAS Development Application Decision Notice 7 of 12
Sewer Mains
39. The site shall be connected to Council’s existing sewerage reticulation systems and be constructed in
accordance with Council’s standards and requirements at no cost to Council.
40. The existing sewer main that is located in the adjoining property on the southern side of the site and the
‘zone of influence’ (taken as the area within a 45-degree angle measured from the invert of the sewer
main to the finished surface level) shall be accurately located and determined by a licensed Surveyor and
shown on all plans submitted for Operational Works approval.
To ensure Council’s sewer main is accessible for maintenance purposes and is protected from risk of
damage, no structures requiring a building permit (eg. buildings, retaining walls exceeding 1m in height,
raised terraces, etc) shall be constructed within this ‘zone of influence’ or within 1.5m of the centreline of
the sewer main, whichever is the greater. As such the applicant shall amend Operational Works plans
including Building plans to ensure compliance.
Town Water Supply
41. The site shall be connected to Council’s existing town water supply and be constructed in accordance with
Council’s standards and requirements at no cost to Council.
42. Each individual water connection to the water reticulation system shall extend to the property boundary
and be metered. All fees for the supply of water meters shall be paid to the Council.
43. All water meters must be located outside the property boundary and in an easily assessable location to
facilitate unhindered reading by Council and/or Council’s contracted water meter readers, and not behind
fences or locked gates. In this regard approval of the water meter configuration and location must be
obtained from Council’s Water & Sewerage Capital Works Manager prior to lodgement and approval of
hydraulic drawings.
44. For Multiple Uses (including Building Format Plans, Group Title Plans, etc) the development shall be
served by:
44.1. A single Body Corporate water meter to measure the total water consumption (including fire hose
reels, but excluding fire hydrants and fire sprinkler systems), and
44.2. Individual water meters to each tenement capable of being separately rated, and
44.3. A fire service (fully testable single detector check with metered bypass), where applicable, for flows
to fire hydrants and fire sprinkler systems (excluding fire hose reels).
Service Easements (Sewer)
45. A registered easement shall be created over the zone of influence of all sewers within the subject site and
over those parts of the subject site that are impacted upon by sewers on any adjoining sites. The
easements shall generally be parallel to and centred over the sewer main and be equivalent in width to
twice the depth to invert level of the sewer at the deepest point within the allotment (measured from the
finished surface) and be no less than 3.0m wide overall. In this regard a licensed surveyor shall
accurately locate all sewer mains and determine the necessary width of the easement, which shall be
shown on any plans submitted for Operational Works / Building Works approval. To this extent the
surveyor shall certify that the sewer and the zone of influence is wholly contained within the easement to
be created.
In addition to this the Applicant’s Solicitor shall give Council’s Solicitor an appropriate undertaking in
writing that the Title Deed and the easement documents will be lodged at the Land Titles Office and any
additional Titles Office forms or requisitions requiring the consent of Council will be attended to promptly.
A duly executed copy of the easement shall be submitted to Council for perusal prior to the use
commencing.
Any changes required by Council’s Solicitor must be corrected immediately.
46. No building or other structure shall be constructed or encroach over an easement.
Earthworks
47. Earthworks carried out on site shall not affect the structural integrity of any of the existing fences and/or
structures and/or buildings and/or services and/or lands that border the development site. Fences that
are affected shall be replaced prior to the Building Certifier issuing the Certificate of Classification. In this
regard any fences to be replaced shall be clearly shown on the plans submitted for Operational Works
approval.
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@700946e8\@[email protected]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED Decision Notice - 010.2007.00000616.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 58 KB (small file)
- File type
No other editions are linked here.