Noosa Plan 2020: Amendment 3
Part 9 Development codes \ 9.5 Other Development Codes \ 9.5.1 Reconfiguring a Lot
Code




 (d)   reticulated water supply;
 (e)   reticulated sewerage; and                         AO12.2                                                      AO12.2 – Not Applicable
 (f)   stormwater drainage.                              If located in a water service area each new lot can be      The site is not in a water service area.
                                                         connected to Unitywater’s water supply network.

                                                         AO12.3
                                                         If located in a sewerage service area each new lot can      AO12.3 – Not Applicable
                                                         be connected to Unitywater’s sewerage network.              The site in a sewerage service area.

                                                         AO12.4
                                                         If located in a Local plan area lots can be connected to    AO12.4 – Not Applicable
                                                         Council’s stormwater drainage network.                      The site is not in a Local Plan Area. Stormwater can
                                                                                                                     be appropriately harvested for rainwater purposes
                                                                                                                     and discharged to a lawful point of discharge within
                                                                                                                     the site.
                                                         AO12.5
                                                         If not in a sewerage service area each lot has sufficient   AO12.5 – Complies
                                                         area and other attributes to ensure efficient and           Each lot has a sufficient area for on-site sewerage
                                                         effective on-site sewerage disposal.                        disposal.

 PO13                                                    AO13.1                                                      AO13.1 – AO13.3 - Complies.
 Each lot is provided with safe and convenient vehicle   Vehicular access for the development is consistent          A Traffic Engineering Letter prepared by Modus
 access                                                  with the function and design of the road it takes access    confirms that Lot 1 can accommodate sufficient sight
                                                         from.                                                       distance and that Lots 2, 3 and 4/5 can
                                                         AO13.2                                                      accommodate sufficient sight distance subject to
                                                         Development does not require new or changed access          minor vegetation clearing within the Black Mountain
                                                         to a state-controlled road that is a limited access road    Range Road verge. Access arrangements are
                                                         unless in accordance with the limited access policy for     therefore considered safe and convenient.
                                                         the state-controlled road .
                                                         AO13.3
                                                         Access easements are in appropriate locations for safe
                                                         access and egress, and supply appropriate widths and
                                                         levels of service for the number of vehicles that will
                                                         utilise them as per the requirements of Council’s
                                                         Planning Scheme Policy PSP6 Engineering design
                                                         standards — Roads, drainage and earthworks.
                                                         Editor's note- Reference should be made to the Queensland
                                                         Government's Development Assessment Mapping System to


Print Date: 23/03/2026                                                                                                                                               Page 8
Log in to download the original file

Appendix B - Code Assessment.pdf · 608 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.