Original source · versioned page text
RFI - 20220156 Kauri St SWMP Rev B
Figure 4.3 - MUSIC Stormwater Treatment Train
4.2.1.1. Pit Inserts
Grated inlet pits within the driveway are to be fitted with Ecosol Litter baskets with 200µm filter bags or approved
equivalent. These have been certified by the manufacturer as having the pollutant removal efficiencies shown in
Figure 4.4 - Ecosol Litter Basket Pollutant Removal Efficiencies. The inserts are modelled using generic treatment
nodes, with a high flow bypass of 53L/s per pit (4 pits have been modelled within the driveway area, with total
bypass of 212L/s) and concentration-based capture efficiency set in accordance with manufacturers guidelines.
Refer to Appendix Ecosol Litter Basket Technical Specifications for further details on the devices and it’s MUSIC
configuration.
Project number 20220156 Page 14 of 27
File RECOR Stormwater Management Report - 20220156.docx, 2022-10-28 Revision 1
P +61 7 5211 1003 A 37 Mary St, Noosaville Qld 4566 E [email protected] recorconsulting.com