Original source · versioned page text
BA250052 Architectural
Attached to the e-mail Generally in Accordance - Revised Design - MCU21/0150.02.
NOTE: BAL RATING 19 COMPLIANCE REQUIRED
AS PER NCC VOL 2 2022
REFER TO ENGINEER'S NOTES:
DESIGN AND SPECIFICATIONS
FOR ALL TIMBER FRAMING, TIE ALUMINIUM FRAMED WINDOWS - INSTALLED
DOWNS, BRACING AND CONNECTION AS PER MANUFACTURER'S SPECIFICATIONS
DETAILS.
ALL EXTERNAL CLADDINGS TO BE
INSTALLED AS PER MANUFACTURER'S
NOTE: TERMITE PROTECTION OF THE BUILDING TO SPECIFICATIONS
BE IN ACCORDANCE WITH AS3660 - PROTECTION
OF BUILDINGS FROM SUBTERRANEAN TERMITES INSTALL FLASHINGS TO NEW WINDOWS AND DOORS
AS PER AUSTRALIAN STANDARD
EXTERNAL WALL SARKING / INSULATION:
WALL SISALATION AND R2 WALL BATTS
TO ALL EXTERNAL WALLS
COLORBOND (TRIMDECK) ROOF SHEET
FLASHINGS/ GUTTER - FIXED AS PER
COLORBOND MANUFACTURER'S SPECIFICATIONS
TRUSSES/RAFTERS - FLASHINGS TO
AS PER ENGINEER'S / ROOF/WALL JOINS 55mm ANTICON
MANUFACTURER'S UNDER ROOF
SPECIFICATIONS 1000
600
DUCT EXHAUST 300
PLASTER
BULKHEADS
14.0° DUCT RANGEHOOD
BULKHEAD 300 7.5°
METAL ROOF BATTENS
TOP PLATE 2 10mm PBD TO RAKED
CEILING / WALLS
TOP PLATE
CEILING METAL CEILING
BATTENS INT/EXT VERANDAH
JOINERY
2600
2550
2540
BATH/L'DRY DINE/KITCHEN
2100
G.F.L
90
G.L
FOOTING/SLAB DESIGN Slab min 225mm 90MM STEP DOWN
AS PER ENGINEER'S TO VERANDAH
SPECIFICATIONS
Section 1
1 : 100
FOR CONSTRUCTION
Rev No. Description Date
1 Concept Floor Plan 12/08/2024 Client: Sophie McLaren
SECTION 1
22/11/2024 12:13:21 PM
2 Concept Plans Selections 23/08/2024 Description: New Dwelling
3 Preliminary Working Drawings 28/08/2024 Project number 6335
4 For Construction 3/10/2024
5 For Construction - Lodgement 15/10/2024 Site Address: 9 Rules Rd Pomona Qld Date 12/08/2024 A108
6 For Construction - Contract 18/11/2024 Drawn by T.D
© QBCC Lic no. 15187645 Checked by T.D Scale As indicated