BA250052 Architectural
Attached to the e-mail Generally in Accordance - Revised Design - MCU21/0150.02.
GENERAL NOTES STRUCTURAL DESIGN WINDOWS
ALL DIMENSIONS IN MILLIMETRES. ALUMINIUM & GLAZING IN ACCORDANCE WITH
WHERE A STRUCTURAL ENGINEER HAS BEEN CONSULTED A.S. 2047 - 2014 - WINDOWS IN BUILDINGS.
ALL TIMBER OR STEEL FRAMED WALLS TO WET AREAS TO BE - ENGINEER'S DRAWINGS AND SPECIFICATIONS TO BE TO SUIT SITE DESIGN WIND LOADING.
LINED WITH FC OR APPROVED WET AREA CLADDING, FIXED STRICTLY COMPLIED WITH.
IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. RETAINING STRUCTURES PROTECTION OF OPENABLE WINDOWS TO COMPLY WITH
NCC VOL 2 2022 PART 11.3.7 AND PART 11.3.8.
SUPSPENDED TIMBER OR STEEL FRAMED FLOORS TO HAVE WET 1. DO NOT BACKFILL RETAINING WALLS UNTIL 21 DAYS WINDOWS TO BE PROTECTED IN BEDROOMS
AREA FLOORING TO ALL WET AREAS, FIXED IN ACCORDANCE AFTER CONCRETE HAS BEEN PLACED IN THE WALLS OF WHERE WINDOW IS 2M OR MORE ABOVE THE SURFACE
WITH MANUFACTURER'S SPECIFICATIONS. THE RETAINING STRUCTURES UNLESS NOTED BENEATH AND OTHER ROOMS WINDOWS WHERE WINDOW
OTHERWISE. IS 4M OR MORE ABOVE SURFACE BENEATH.
THE SUB-FLOOR SPACE OF A DWELLING MUST BE VENTILATED IN 2. THE BACKFILL MATERIAL BEHIND THE FULL LENGTH OF
ACCORDANCE WITH NCC VOL 2 2022 PART 6.2.1 THE EARTH RETAINING WALLS SHALL CONSIST OF A LININGS
COARSE GRAINED SOIL OF HIGH PERMEABILITY (ie CLEAN
ALL GLAZING TO COMPLY WITH NCC VOL 2 2022 PARTS 8.2, 8.3, 8.4 AND MUST BE COURSE SAND OR GRAVEL) TO MAX WIDTH OF 300MM EXTERNAL CLADDINGS AND INTERNAL LININGS
DESIGNED FOR THE WIND LOADS SPECIFIC TO THE BUILDING. FOR THE FULL RETAINING HEIGHT. TO BE FIXED AND FINISHED IN ACCORDANCE
WITH MANUFACTURER'S SPECIFICATION.
SMOKE ALARMS MUST BE INSTALLED IN ACCORDANCE WITH NCC VOL 2 2022
PART 9.5, BE MAINS AND INTERCONNECTED AND COMPLY WITH AS3786 WET AREA SURFACES TERMITES
WATER CLOSETS (WC'S) TO HAVE A MINIMUM CLEAR WIDTH OF 900MM FLOOR SURFACES TO BATH & LAUNDRY SHALL BE IMPERVIOUS, A TERMITE MANAGEMENT SYSTEM MUST BE INSTALLED IN
WITH JUNCTIONS BETWEEN WALL AND FLOOR FLASHED TO ACCORDANCE WITH NCC VOL 2 2022 PART 3.4 & AS3660
DOORS TO WC'S WHICH SWING 'IN' ARE TO HAVE LIFT - OFF HINGES. PREVENT MOISTURE PENETRATION INTO WALLS. - TERMITE MANAGEMENT FOR A SLAB CONFORMING WITH
PROVIDE ADEQUATE CLEARANCE AT TOP OF DOOR TO SUIT HINGES. AS2870 - RESIDENTIAL SLABS & FOOTINGS - CONSTRUCTION.
CERAMIC TILES OR OTHER APPROVED IMPERVIOUS MATERIAL
ALL OTHER CONNECTIONS TO BE IN ACCORDANCE WITH A.S. A1684.2 TIMBER TO WALLS ABOVE SHOWERS TO 1800MM MIN ABOVE FLOOR. TERMITE BARRIERS MUST BE INSTALLED IN ACCORDANCE
FRAMING CODE. WITH MANUFACTURERS RECOMMENDATIONS OR BY AN
SUSTAINABLE BUILDING NOTES: ACCREDITED TECHNICIAN.
STAIRS SHALL BE DESIGNED IN ACCORDANCE WITH NCC VOL 2 2022 PART 11.2. MP 4.1 - ACCEPTABLE SOLUTIONS
RISERS (R) - 115MIN, 190 MAX
GOINGS (G) - 240 MIN (Class 1 &10), 355 MAX; 1. HOME ADDITIONS TO HAVE ENERGY EFFICIENT LIGHTING BUSHFIRE HAZARD AREAS
2R+G = 550 MIN, 700 MAX FOR A MINIMUM OF 80% OF TOTAL FIXED INTERNAL LIGHTING.
2. HOME ADDITIONS TO HAVE NEW AIRCONDITIONERS WITH BUSHFIRE HAZARD AREAS ARE TO COMPLY WITH AS3959 &
MAXIMUM OPENING = 125 mm
AN E.E.R OF 2.9 MIN. NCC VOL 2 2022 - PART G5
STAIR TREADS MUST HAVE A SLIP RESISTANT FINISH OR A SUITABLE NON 3. HOME ADDITIONS TO HAVE ALL SHOWER ROSES AND TAPS
SKID STRIP NEAR THE EDGE OF THE NOSINGS IN ACCORDANCE WITH SERVING LAUNDRY TUBS, KITCHEN SINKS AND BASINS WITH
NCC VOL 2 2022 PART 11.2.4. A MIN 3 STAR WATER EFFICIENCY LABELLING AND STANDARDS
RATING. ALL TOILET CISTERNS TO HAVE A DUAL FLUSH
ALL BALUSTRADES AND HANDRAILS TO BE 1000 MIN ABOVE FINISHED SYSTEM AND A MIN 4 STAR WATER EFFICIENCY LABELLING AND
FLOOR LEVEL, 865mm MIN ABOVE STAIR NOSINGS AND HAVE NO OPENINGS STANDARDS RATING.
GREATER THAN 125mm, IN ACCORDANCE WITH NCC VOL 2 2022 PART 11.3
OTHER
ALL LAMINATED TIMBER BEAMS TO HAVE FULL-WIDTH BEARING AT VEHICLE CROSS OVERS SHALL COMPLY WITH LOCAL
EACH END UNLESS OTHERWISE NOTED BY MANUFACTURERS AUTHORITY REQUIREMENTS.
SPECIFICATION REQUIREMENTS.
FIRE & ACOUSTIC SEPARATION
CONCRETE MASONRY DESIGN TO AS 3700.
BUILT TO BOUNDARY WALLS & SEPARATING WALLS
WRITTEN DIMENSIONS TO HAVE PREFERENCE OVER SCALED BETWEEN TWO OR MORE CLASS 1 BUILDINGS MUST BE IN ACCORDANCE
DIMENSIONS WITH NCC VOL 2 2022 - PART H3 FIRE SAFETY
AND PART F7 - SOUND INSULATION.
ALL ASPECTS OF THIS PROJECT TO COMPLY WITH THE WORK
HEALTH AND SAFETY ACT 2011 & AS AMENDED.
IT IS AT THE BUILDERS DISCRETION TO POSITION BULKHEADS OR SERVICE
PANELS UNDER FLOOR FRAMING TO ACCOMODATE PLUMBING SERVICES.
FOR CONSTRUCTION
Rev No. Description Date
1 Concept Floor Plan 12/08/2024 Client: Sophie McLaren
DETAIL NOTES
22/11/2024 12:13:14 PM
2 Concept Plans Selections 23/08/2024 Description: New Dwelling
3 Preliminary Working Drawings 28/08/2024 Project number 6335
4 For Construction 3/10/2024
5 For Construction - Lodgement 15/10/2024 Site Address: 9 Rules Rd Pomona Qld Date 12/08/2024 A101
6 For Construction - Contract 18/11/2024 Drawn by T.D
© QBCC Lic no. 15187645 Checked by T.D Scale 1 : 100