Central Basin: CONCEPT DETENTION BASIN DESIGN CALCULATIONS
File:      H:\B14\150-199\B14158.W\01 Final Layout Op Works\SW_Quantity\[B14158.W_Detention Basin Design (Master Layout).xls]WeirB
Date:      11/01/2017
User:      BP
Note:      Storage and outlet calcs for Detention Basin

STAGE - STORAGE RELATIONSHIP FOR WBNM
Stage areas taken from ACAD model
                                                 Accumulated Vol.
   RL      Area. (m2)         Vol. (m3)                (m3)
  99.2            1950                                  0
  99.3            2108                                  0
  99.4            2265                                  0
  99.5            2423                                  0
  99.6            2581            0                     0            Primary Front Orifice
  99.7            2739           266                   240
  99.8            2896           282                   491
  99.9            3054           298                   751
   100            3212           313                  1,021
  100.1           3369           329                  1,301
  100.2           3527           345                  1,591
  100.3           3685           361                  1,891
  100.4           3842           376                  2,202
  100.5           4000           392                  2,523          Primary Outlet Pit
  100.6           4100           405                  2,944
  100.7           4200           415                  3,379
  100.8           4300           425                  3,828
  100.9           4400           435                  4,291          Major Overflow Weir
   101            4500           445                  4,774
  101.1           4600           455                  5,272
  101.2           4700           465                  5,783
  101.3           4800           475                  6,308          Min. Embankment Level

OUTLET CALCULATIONS
                                                 Primary Side          Primary Front                                          Major Overflow
                         Bio Filtration Basin                                              Primary Outlet Pit   Outlet Pipe
Type                                                Orifice               Orifice                                                  Weir
Length                                                                                            1.2               20
Width                                                                                             1.2
No.                                                      2                     2                                    1
Dia (m)                                                 0.4                   0.4                                 0.825
Height (m)
Area (m2)                                                                                        1.44              0.53
Invert Level (R.L)                                     99.6                  99.6               100.45             98.3           100.9
Inflow Level (R.L)                                     99.6                 99.60               100.45             99.6
D/S HGL (R.L)                                                                                                     0.000
f (Fig 1.6)                                                                                                       0.022
Pit Loss (K)                                                                                                        1
Hyd Cond. (k) (m/hr)
Depth Media d (m)
Perimeter (m)                                                                                     4.8                               12
% Opening Clear *                                                                                75%

STAGE - DISCHARGE RELATIONSHIP FOR WBNM
                                                                                                                                                  Total
            Accum.
   RL                     Bio Filtration Basin    Circular Inlet 1      Circular Inlet 2         WEIR 1           PIPE 1       WEIR Overflow   Discharge
            Vol. (m3)
                                                                                                                                                 (m3/s)
   99.6           0             0.00                  0.00                0.00                 0.00               0.00             0.00           0.00
   99.7          240            0.00                  0.03                0.03                 0.00               1.43             0.00           0.06
   99.8          491            0.00                  0.09                0.09                 0.00               1.50             0.00           0.17
   99.9          751            0.00                  0.17                0.17                 0.00               1.56             0.00           0.33
    100         1021            0.00                  0.27                0.27                 0.00               1.62             0.00           0.53
  100.1         1301            0.00                  0.39                0.39                 0.00               1.68             0.00           0.77
  100.2         1591            0.00                  0.43                0.43                 0.00               1.74             0.00           0.87
  100.3         1891            0.00                  0.48                0.48                 0.00               1.79             0.00           0.96
  100.4         2202            0.00                  0.52                0.52                 0.00               1.85             0.00           1.04
  100.5         2523            0.00                  0.56                0.56                 0.09               1.90             0.00           1.21
  100.6         2944            0.00                  0.60                0.60                 0.46               1.96             0.00           1.66
  100.7         3379            0.00                  0.64                0.64                 1.00               2.01             0.00           2.01
  100.8         3828            0.00                  0.67                0.67                 1.65               2.06             0.00           2.06
  100.9         4291            0.00                  0.71                0.71                 2.15               2.12             0.00           2.12
    101         4774            0.00                  0.74                0.74                 2.38               2.17             0.66           2.83
  101.1         5272            0.00                  0.77                0.77                 2.58               2.22             1.93           4.15
  101.2         5783            0.00                  0.80                0.80                 2.78               2.27             3.68           5.95
  101.3         6308            0.00                  0.84                0.84                 2.96               2.31             5.85           8.16
Note:
The following equations have been used to calculate flow capcaties for the
outlet types for each stage:
Sand Filter Equation (NSW EPA 1997)                              Q = A x k(h+d) / d
Pipe Flow (M.J.Boyd 1972)                                        Q = 0.421 x g0.5 x Dia0.87 x HW 1.63 (where HW/Dia < 1.2)
                                                                 Q = 0.53 x g0.5 x Dia1.87 x HW 0.63 (where HW/Dia > 1.2)
                                                                 where g = 9.81m/s2
Weir Equation (AR&R Equ. 14.5)                                   Qi = 1.66 x P x d1.5
Orifice Equation (AR&R Equ. 14.6)                                Qi = 0.67 x A x (2g x d)0.5
HGL Calculation (as per Section 5.21 QUDM)
Log in to download the original file

Appendix B - Amended Biome Consulting Response.PDF · 16.0 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.