7.0        RESIDENTIAL USE CODE
7.1.1      The table below is an assessment of the proposed development in accordance with the Specific Outcomes and
           Probable Solutions of the Residential Use Code.

7.1.2      Table 14.21. Division 6 – Specific Outcomes and Probable Solutions for all Residential Uses.

7.1.3      Table 14.24 Division 6 – Specific Outcomes and Probable Solutions for Multiple Housing Typee 4 – Conventional

                    Table 14 – 21 Specific Outcomes and Probable Solutions For All Residential Uses

                      Column 1                                                             Column 2
                   Specific Outcomes                                        Probable solutions (if code assessable)
                                                       14.52 Effects of use
Electricity supply infrastructure                           S1.1 No solution provided
O1 The development does not adversely impact on             S2.1 Development for uses adjacent to or
existing or future electricity supply infrastructure;       within 50m of an existing electricity substation
AND                                                         incorporates noise attenuation measures to
O2 All uses and works maintain an adequate safe             mitigate noise impacts;
distance from electrical infrastructure including           AND
substations, overhead powerlines, power poles and           S2.2 Buildings and structures (including
transformers                                                swimming pools, sheds, tennis courts or
                                                            outbuildings) are not constructed under
                                                            overhead electricity transmission lines, or
                                                            within electricity easements;
                                                            AND
                                                            S2.3 A minimum separation distance is
                                                            maintained from the electricity transmission
                                                            line to the closest boundary of habitable
                                                            buildings and child activity areas, as follows—
                                                            a) 20m for transmission lines up to 132kV;
                                                            b) 30m for transmission lines between
                                                            133kV and 275kV; and
                                                            c) 40m for transmission lines greater than
                                                            275kV
Complies
O1 – O2 The existing electricity and supply infrastructure will sustain the proposed development and will not adversely impact
on the existing or future infrastructure of the area. We advise this application is merely a Material Change of Use over the
existing detached house with only minor internal building works proposed.
14.53 Environmentally Sustainable Building Design
Hot Water Systems                                           S3.1 All hot water systems installed are—
O3 Hot water systems are installed and operated to          a) solar systems; or
support the efficient use of natural resources and          b) electric heat pump systems; or
minimise consequent pollution such as greenhouse gas c) natural gas or LPG systems; or
emissions.                                                  d) any combination of a), b) or c).
Complies
O3 The existing hot water systems servicing the site will remain and no change is proposed as part of this application.
Water supply and conservation                               S4.1 If in a designated rainwater tank area as
O4 On-site water storage is designed and operated to        identified in Map 1 of Schedule 8, residential
support the efficient use of water;                         uses that qualify as class 1A or 1B structures
AND                                                         under the Building Code of Australia have a
O5 On-site water storage is adequate for occupants every rainwater tank or tanks in accordance with
day use and fire fighting purposes.                         Schedule 8.
                                                            AND
                                                            S5.1 Where not in a water service area a
                                                            rainwater tank of a minimum of 60,000 litres is
                                                            provided for each dwelling unit, with the
                                                            exception of Multiple Housing Type 1.



                              11 Allambi Rise, Noosa Heads • BRSS2403-000 • 21st August 2007

Used in these records

About this file

File size
797 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

BRSS2403-000_Final Report_210807.pdf [As Published].pdf · 797 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.