ACOUSTICS & AIR QUALITY
Appendix E MP4.4 Construction Requirements
Table E.1 Acceptable Forms of Construction
Component
Minimum
of Buildings
Acoustic Rating Acceptable Forms of Construction
External
(Rw)
Envelope
Noise Category 3
38 Minimum 14.38mm thick laminated glass, with full perimeter
(where total acoustically rated seals;
area of glazing OR
for a habitable Double glazing consisting of one pane of minimum 5mm thick
room is greater glass and one pane of minimum 6mm thick glass with at least
than 1.8m2) 44mm air gap, and full perimeter acoustically rated seals
Glazing 35
(where total
area of glazing
Minimum 10.38mm thick laminated glass, with full perimeter
for a habitable
acoustically rated seals.
room is less
than or equal to
1.8m2)
Two leaves of clay brick masonry at least 110mm thick with:
(i) cavity not less than 50mm between leaves; and
(ii) 50mm thick mineral insulation or 50mm thick glass wool
insulation with a density of 11kg/m3 or 50mm thick polyester
insulation with a density of 20kg/m3 in the cavity.
OR
Two leaves of clay brick masonry at least 110mm thick with:
(i) cavity not less than 50mm between leaves; and
(ii) at least 13mm thick cement render on each face
OR
External 47 Single leaf of clay brick masonry at least 110mm thick with:
walls (i) a row of at least 70mm x 35mm timber studs or 64mm
steel studs at 600mm centres, spaced at least 20mm from
the masonry wall; and
(ii) Mineral insulation or glass wool insulation at least 50mm
thick with a density of at least 11 kg/m3 positioned between
studs; and
(iii) One layer of plasterboard at least 13mm thick fixed to
outside face of studs.
OR
Single leaf of minimum 150mm thick masonry of hollow,
dense concrete blocks, with mortar joints laid to prevent
moisture bridging.
41 Concrete or terracotta tile or metal sheet roof with sarking,
Roof plasterboard ceiling at least 10mm thick fixed to ceiling joists,
glass wool insulation at least 50mm thick with a density of at
7617R01V01.docx Page 45
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
J ACOUSTIC REPORT.PDFRelated documentApplication case desk ↗
About this file
- File size
- 7.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.