Council archive · source document
J Acoustic Report · 132007.2398
Attached to the e-mail 132007.2398.02 Request to change existing approval (3 of 3) - Traffic Impact & Acoustic reports.
ACOUSTICS & AIR QUALITY
Component
Minimum
of Buildings
Acoustic Rating Acceptable Forms of Construction
External
(Rw)
Envelope
least 11kg/m3 or polyester insulation at least 50mm thick
with a density of at least 20kg/m3 in the cavity.
OR
Concrete suspended slab at least 100mm thick.
Concrete slab at least 100mm thick
OR
Tongued and grooved boards at least 19mm thick with:
(i) timber joists not less than 175mm x 50mm; and
(ii) mineral insulation or glass wool insulation at least 75mm
thick with a density of at least 11kg/m3 positioned between
45 joists and laid on plasterboard at least 10mm thick fixed to
Floors
underside of joists; and
(iii) mineral insulation or glass wool insulation at least 25mm
thick with a density of at least 11kg/m3 laid over entire floor,
including tops of joists before flooring is laid; and
(iv) secured to battens at least 75mm x 50mm; and
(v) the assembled flooring laid over the joists, but not fixed to
them, with battens lying between the joists.
Fixed so as to overlap the frame or rebate of the frame by not
less than 10mm, fitted with full perimeter acoustically rated
33 seals and constructed of -
Entry doors
(i) solid core, wood, particleboard or blockboard not less than
45mm thick; and/or
(ii) acoustically laminated glass not less than 10.38mm thick.
Noise Category 2
35
(where total
area of glazing Minimum 10.38mm thick laminated glass, with full perimeter
for a habitable acoustically rated seals.
room is greater
than 1.8m2)
Glazing 32
(where total
area of glazing
Minimum 6.38mm thick laminated glass with full perimeter
for a habitable
acoustically rated seals.
room is less
than or equal to
1.8m2)
Two leaves of clay brick masonry at least 110mm thick with
cavity not less than 50mm between leaves
OR
41 Single leaf of clay brick masonry at last 110mm thick with:
External
walls (i) a row of at least 70mm x 35mm timber studs or 64mm
steel studs at 600mm centres, spaced at least 20mm from
the masonry wall; and
(ii) mineral insulation or glass wool insulation at least 50mm
thick with a density of at least 11 kg/m3 positioned between
7617R01V01.docx Page 46
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
J ACOUSTIC REPORT.PDFRelated documentApplication case desk ↗
About this file
- File size
- 7.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.