Council archive · source document
SUPERSEDED Decision Notice - 010.2007.00002174.001 [As Published] · 132007.2174
-3-
10. The proposed development shall have all kitchen, laundry and bathroom fittings that comply
with the AAA Water Conservation Rating System as defined by the AS/NZS 6400 (Water
Efficient Products - Rating and Labelling 2003) and AS/NZS 3500 (National Plumbing and
Drainage Standard Part 1.2), with toilets to comply with the AAAA Water Conservation Rating
System. All tap ware and shower roses shall not exceed a maximum flow of 9 litres per min.
Dishwashers and washing machines are excluded from this requirement.
11. Security in the form of a cash bond or trading bank guarantee to the sum of $10 000 must be
submitted, to secure performance of all conditions of this approval, prior to the issue of a
Development Permit for operational works. The cash bond or trading bank guarantee will be
returned on performance of the conditions of approval less any costs incurred by Council in
respect of enforcing performance of this permit.
12. The requirements of this development approval are to be effected, prior to the use of the
premises. Council reserves the right to call upon the bond or guaranteed sum referred to in
this approval to effect compliance with conditions.
13. The developer must obtain all of the other Development Permits referred to in the Decision
Notice, prior to obtaining a Development Permit for Building Works.
Land Development
Lot Amalgamation
14. All separate, adjoining lots that form part of this application shall be amalgamated into one
undivided allotment in accordance with Section 3.7.3 of the Integrated Planning Act and the
Plan of Survey submitted for registration at the Land Titles Office. Proof of title being issued
for the amalgamated lot shall be submitted to Council prior to the issue of the Development
Permit for Operational Works.
Vehicle Access
15. A vehicular access driveway to serve the proposed building shall be constructed from the
Elanda Street frontage of the site with a width of 5.5m for the first 6 metres from the kerb line.
16. The driveway shall be designed and constructed to Council’s design standards and to grades
that prevent vehicles from scraping and/or bottoming whilst also allowing pedestrians
movements along the footpath without any step or level difference. Should any driveways be
constructed to grades that do not comply with AS/NZS 2890.1-2004, Council will require that
the driveway be removed and reconstructed to levels that do comply.
Please note, a step between the driveway and the footpath shall be avoided, as it is preferred
to have the footpath continue at a constant grade to minimise the potential for pedestrians to
trip or fall.
17. To ensure pedestrian safety between vehicles exiting the site and pedestrians on the footpath,
the driveway and any associated fencing or vegetation near the driveway shall comply with the
minimum sight line requirements as defined in AS 2890.1, section 3.2.4. The applicant shall
demonstrate compliance by illustrating these sight lines on the plans submitted for both
Operational Works approval and Building Works approval.
Car Parking
18. Carparking shall be provided within the site generally as shown on drawing number
0710SD.04 (A) dated August 2007 by Ian Gorton Design, except as modified herein.
19. A minimum of 8 car park spaces shall be provided on site.
20. A turning area shall be provided, in lieu of the uncovered visitor carpark space, or by
lengthening the uncovered visitor car park, to provide additional area for car turning to allow
vehicles to turn around and leave the site in a forward gear when the carpark is full.
Page 3 of 15
See the original