SUPERSEDED Decision Notice - 010.2007.00002174.001 [As Published] · 132007.2174

of 15

Text shows just the words. Original shows the document exactly as it was published.

                                                -4-



21.   The carparking area shall be designed to comply with the provisions of AS/NZS 2890.1-2004
      for user class 1A with allowance for vehicles to enter and leave the site in a forward gear and
      with a minimum head clearance (headroom) at any point of 2.2m.
Vegetation Protection & Preservation
22.   Where retained trees are located in areas proposed to be filled on site (or are located on
      neighbouring allotments to the actual site to be filled), there will be a need to prevent fill
      material from being placed on the trees root system. To this end the design of the filling works
      will need to incorporate terracing around the tree or a similar means of ensuring that the
      natural ground level around the trees remains generally the same as existing. These
      measures shall clearly be shown on the plans submitted for Operational Works approval and
      any drainage required to drain these areas shall also be shown on the plans.
Roadworks Widening
23.   The full length of the Elanda Street frontage of the development site shall be upgraded by
      providing kerb & channel to be consistent with and match smoothly with the adjoining sections
      of kerb and channel, bitumen road widening and landscaping improvements to the footpath.
      All associated and ancillary work including any pavement correction to the existing pavement,
      drainage works, modification of the footpath, and adjustments to the existing infrastructure
      shall be undertaken to complete the roadworks widening.
      In this regard a schedule of works, specifications and plans detailing this work shall be
      prepared and submitted to Council for approval prior to obtaining a Development Permit for
      Operational Works.

Frontage Works
24.   Footpath improvements such as topsoiling, grassing, and tree planting are required to the
      Elanda Street frontage of the site in accordance with Planning Scheme Policy PSP03
      Landscaping Plants & Guidelines. Grass shall be couch, free of weeds.
25.   A new 1.5m wide concrete path shall be constructed along the frontage of the site in
      accordance with Council’s design standards and with an alignment that protects any
      significant vegetation or any underground services and match smoothly with adjoining paths. A
      Development Permit for Operational Works shall be required.
26.   All paths, driveways and parking areas shall be designed and constructed to ensure
      pedestrian safety using non-slip materials, to produce an evenly graded surface finish, and to
      be in accordance with the Disability Discrimination Act 1992 and Australian Standard 1428.1
      Design for Access & Mobility.
Roof Water & Stormwater Drainage
27.   The stormwater disposal from the site shall be generally in accordance with the Stormwater
      Quantity Management Plan dated January 2008 reference AA07731SMP by Duke
      Environmental.
28.   Roof runoff from any new building shall be directed to a rainwater storage system or tank
      (minimum storage 3000 litres per attached dwelling unit) that is installed to ensure water from
      the tank is used for external uses (such as watering gardens, irrigation, ornamental ponds,
      water features, topping-up swimming pools, outdoor cleaning, etc) and for use in flushing of
      toilets internal to the building.   All rainwater tanks are to be designed and installed in
      accordance with the Queensland Development Code (QDC), and shall be part of the plumbing
      application in conjunction with the building approval. The location and capacity of the tanks
      shall be clearly shown on the plans submitted for Building Works and Operational Works
      approval and any overflow shall be directed to the onsite detention and infiltration system.




                                                                                           Page 4 of 15

Used in these records

About this file

File size
84 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

SUPERSEDED Decision Notice - 010.2007.00002174.001 [As Published].pdf · 84 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.