Assessment Managers Conditions:
General:
Pursuant to the provisions of the Sustainable Planning Act 2009 and the Building Act 1975, permission to undertake the
building work as outlined above is subject to the following conditions:
1. The builder must ensure a notice of inspection is given to Pacific BCQ, (Ph: 5412 1520) before proceeding past
the following stages of construction.
Please note: a minimum of 24 Hours’ Notice is required for inspections, work is not to progress past a mandatory
stage until Pacific BCQ or a competent person lawfully acting on our behalf has given authority to proceed.
Mandatory STAGE undertaken by
Building General
Pacific
Footing excavations (including pier holes) with reinforcing steel in place, prior to the
BCQ
placement of concrete.
RPEQ*
Building set out, confirming the siting of the building/s in accordance with the boundary Registered
clearance shown on the approved plans, prior to the placement of concrete. Surveyor
Pacific
Slabs, including suspended slabs, with formwork and reinforcing steel in place prior to the
BCQ
placement of concrete.
RPEQ*
Pacific
Masonry Block Work, with reinforcing steel in place, prior to the placement of concrete. BCQ
RPEQ*
Pacific
Framing, including structural members, tie-down and bracing prior to the installation of
BCQ
linings.
RPEQ*
Pacific
Final, on completion of all works relating to this approval.
BCQ
Pacific
As may be required by the Building Certifier.
BCQ
Inspections will be undertaken in accordance with the Guidelines for inspection of Class 2 to 9 Buildings Version 1
as published by Dept. of Housing and Public Works dated 29/06/2012.
Where inspections are to be undertaken by Registered Professional Engineer of Queensland (RPEQ*), Pacific BCQ
must be advised of their Name and Registration Number prior to the event.
2. Certification and Documentation: The following certificates of inspection and compliance and or additional
documentation is to be submitted from a suitably qualified person prior to the issue of a Form 11 – Certificate of
Classification, or prior to proceeding past the nominated stage of work:
CERTIFICATE TYPE REQUIRED
Registered Professional Engineer of Queensland (RPEQ*)certificates of satisfactory inspection of:
Footings (including pier holes). Form 16
Floor Slabs (including suspended slabs). Form 16
Masonry Block Work. Form 16
Structural (framing bracing and tie down). Form 16
Registered Land Surveyor certificates of confirmation covering the following elements:
Set-out. See Note 2
Competent Persons Design or Aspect Certificates (as indicated) covering the following elements:
Termite Barrier installation including diagram of treated areas. Form 16
Roof Trusses and Truss Layout. Form 15
Glass and window. Form 15
Waterproofing application. Form 16
Electrical systems: Emergency lighting See Note 2
Electrical systems: Exit signs See Note 2
Hydraulic systems: Fire hose reels Form 16