Skip to the record
For the highest quality transcripts.

Council archive · source document

SUPERSEDED - Council Meeting - Decision Notice - Minor Change - MCU16 0090 02 [As Published] · MCU16/0090.02

of 9

Text shows just the words. Original shows the document exactly as it was published.

                      Stormwater Drainage
               19.    Stormwater runoff from the development must be disposed of on-site without causing scour
                      or damage to the subject site or any adjoining property. The works must be undertaken in
                      accordance with an Operational Works approval and must include in particular:
                      a.      collection of runoff from the buildings and hardstand areas
                      b.      collection of runoff from the carparking areas and access aisles
                      c.      certification from an RPEQ that states the development of the site will not create a
                              worsening for downstream properties in regard to stormwater quality or quantity.
                      Earthworks and Retaining Walls
               20.    All fill and associated batters must be contained entirely within the subject site unless written
                      permission from the respective landowner(s) is provided to Council.
                      Damage to Services and Assets
               21.    Any damage caused to existing services and assets as a result of the development works
                      must be repaired at no cost to the asset owner at the following times:
                      a.      where the damage would cause a hazard to pedestrian or vehicle safety, immediately;
                              or
                      b.      where otherwise, upon completion of the works associated with the development.
                      Any repair work which proposes to alter the alignment or level of existing services and assets
                      must first be referred to the relevant service authority for approval.
                      Noise
               22.    Mechanical plant and equipment, a/c units, motors, refrigeration equipment, compressors,
                      pumps etc on site should be situated within the building or suitably provided with noise
                      reduction measures and located as to prevent a noise nuisance beyond the boundary of the
                      site and not exceed the levels specified in Table 1.
                                                                  TABLE 1

                                                 NOISE LIMITS AT A SENSITIVE RECEPTOR

                                            Noise level at noise sensitive place measured as the adjusted
                            PERIOD
                                                        maximum sound pressure level (L10, adj,T)

                           7am – 6pm                      Background noise level (L90,T) plus 5 dB(A)

                        6pm – 10pm                           Background noise level plus 5 dB(A)

                        10pm – 7am                            Background noise level plus 3 dB(A)

                                                  NOISE LIMITS AT A COMMERCIAL PLACE

                                              Noise level at a commercial place measured as the adjusted
                            PERIOD
                                                         maximum sound pressure level (L10, adj,T)

                           7am – 6pm                      Background noise level (L90,T) plus 10 dB(A)

                           6pm – 10pm                        Background noise level plus10 dB(A)

                           10pm – 7am                         Background noise level plus 8 dB(A)




                                                                                                         Page 4 of 9
Document Set ID: 22512549
Version: 5, Version Date: 26/07/2023

Used in these records

About this file

File size
174 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

SUPERSEDED - Council Meeting - Decision Notice - Minor Change - MCU16 0090 02 [As Published].pdf · 174 KB (small file)