               Table 1: Calculated Hydraulic Wastewater Flows from DEHP (formerly DNR&M)
                                                                        Daily Sewage
                                                         Rooms per                          Total Daily Sewage             Adopted Total
          Item             Source          Quantity                    Flow per Room
                                                          Structure                            Flow (L/day)                 Flow (L/day)
                                                                           (L/day)
           1            Bungalow(s)            3              2           300 – 6001            900 – 1 800                    1,350
           2            Long House             1              4          225 – 4502             900 – 1 800                    900
                           Onsite
           3             Caretaker’s           1              1          225 – 4502              225 – 450                     225
                       Residence (Two
                       Resident Staff)
                       Additional Staff
           4           Accommodation           1              1          225 – 4502              225 – 450                     225
                         (Two Staff
                         Members)
                                                                                                      Total (L/day)            2,700
               Note: 1Flow per person based on two (2) bedroom Apartment/Home Unit with reticulated water supply
                      2Flow per person based on one (1) bedroom Apartment/Home Unit with reticulated water supply




               The hydraulic loading associated with the non-resident staff population can be
               most reliably calculated using the DEHP (formerly DNR&M) Determining
               Capacity of Sewage Treatment Plants Based on Use Conditions, as follows:

               Table 2: Calculated Hydraulic Wastewater Flows from DEHP (formerly DNR&M)

                                                                                                        Total Daily Sewage Flow
               Item              Source              Population          Flows (L/day/pp)
                                                                                                                 (L/day)
                           Non-Resident Staff
                  1       Member (E.g. General            1                     301                                   30
                               Manager)
                             Non-Resident
                  2          Cleaning Staff               2                     15                                    30
                               Members

                                                                                      Total (L/day)                   60
                      1Flow per person based on Non-Resident Staff at Hotels/Motels type facility



               Based on the above references, a total hydraulic loading of 2,760 litres per day
               (14EP) can be estimated for the guest and staff accommodation
               facilities/population at the Makepeace Island accommodation facility.
               On-Site Wastewater Land Application Area

               Effluent irrigation currently occurs via subsurface dripper lines within the existing
               raised garden beds, totalling 540m2.

               Based on the estimated hydraulic loading of 2,760L/day, the required effluent
               irrigation area can be determined using Design Irrigation Rate (DIR) calculation
               as set out in Table M1 of AS1547:2012.


p: 07 5450 2688                                    e: [email protected]                                    PO Box 1250, Buddina Q 4575
f: 07 5450 2686                                    www.future-plus.com.au                                        ABN 23 658 506 336

Used in these records

About this file

File size
1.1 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

REFERENCED DOCUMENT Assessment of Existing Wastewater Infrastructure - MCU13_0064.pdf · 1.1 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.