2 The overall outcomes sought by the Water Sensitive Design Code are to ensure that—
a) all urban development has suitable treatment and reuse systems for all site run-off;
b) all urban development reduces the need for mains water by utilizing run-off from appropriate areas for applications such as toilet flushing and garden
maintenance;
c) pipeless stormwater management systems are utilised;
d) downstream ecosystems, properties and infrastructure are not adversely impacted by either quantity, levels of inundation or water quality changes
caused by development; and
e) water reuse facilities have no adverse impact on the quality of the town mains water.
Specific outcomes, acceptable solutions and probable solutions for the Water Sensitive Design Code
The specific outcomes sought for the Water Sensitive Design Code are included in column 1 of Table 14-61. Probable solutions for code assessable development
are included in column 2 of Table 14-61.
SPECIFIC OUTCOMES PROBABLE SOLUTIONS COMMENTS
Water reuse S1.1 Development complies with the water Complies.
O1 Development uses a combination of detention quality standards in Table 2 of the SEQ To be incorporated into the design of the future
SPECIFIC OUTCOMES PROBABLE SOLUTIONS COMMENTS
and retention systems to capture run-off from areas Regional Plan Implementation Guideline No. dwellings on the proposed allotments.
on the site; 7 for Water Sensitive Urban Design;
SPECIFIC OUTCOMES PROBABLE SOLUTIONS COMMENTS
AND
O2 Water storage devices must have sufficient S2.1 No solution provided.
capacity having regard to local rainfall pattern and the
catchment area of roof or other hard standing surface;
AND
O3 Captured water is utilised for all non-potable
uses on site; S3.1 Captured water is plumbed to be
available for all external uses including
AND gardening, irrigation, ponds, filling swimming
pools and outdoor cleaning, as well as all
ground floor toilet cisterns and washing
machine cold taps;
AND
S3.2 Where the captured water is used for
toilet flushing and/or laundry use, an
Reconfiguring of a Lot – Three (3) into Four (4) Lots
8 Stevens Street, Sunshine Beach
RPD: Lots 675 and 697 on RP48111 and Lot 676 on SP125656 63
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
REC14/0007 & OPW14/0253 ReportRelated documentApplication case desk ↗
REC14/0007 & OPW14/0253 ReportRelated documentApplication case desk ↗
About this file
- File size
- 1.5 MB (small file)
- File type
No other editions are linked here.