                                                                                       2009/768



2.    The development shall be carried out in accordance with the approved plans listed below or as
      modified herein.
3.    Landscaping Plans for the development shall be submitted as a separate Operational Works
      application. A Development Permit for Building Works shall not be granted until a
      Development Permit for Operational Works – Landscaping has been issued.
4.    Provide the “missing link” connection between the existing pathway adjacent to the
      development site and the proposed footpath in Elanda Street. The width of pathway to match
      the existing pathway width.
5.    Roof and surface runoff connection to Council’s drainage system shall be as shown on
      drawing No. K1595-SW001 -A.
6.    A Traffic Management Plan (TMP) for the development addressing all construction phases
      shall be prepared by suitably qualified persons and submitted to Council for approval prior to
      the pre start meeting. The TMP shall address, but not be limited to, all items listed below, and
      shall be flexible in that it addresses all stages of the development:-
      6.1.   A single nominated access location to and from the site.
      6.2.   The plan should detail the routing of trucks to and from the site.
      6.3.   Provision of onsite parking for personnel working on this development, as there is
             limited parking available in adjacent streets.
      6.4.   Provision of safe cycle and pedestrian movements in the vicinity of the development
             on Elanda Street and adjacent public pathway.
      6.5.   No queuing of trucks is permitted on residential streets, especially prior to 7.00am.
             Further parked trucks must have engines turned off.
      6.6.   Provision of signage and traffic controllers in accordance with Manual of Uniform
             Traffic Control Devices and Transport Infrastructure (Roads) Act.
      6.7.   Provide an indication where the surplus spoil is to be transported to, and/or source of
             imported fill material.
7.    A footpath 1.5 metres wide shall be constructed across the full frontage of the development.
      The footpath shall have a slip resistant surface. The alignment shall be determined on site with
      Council’s Construction Technical Officer. The expansion joints in any footpath shall be
      “sawcut”, not trowel jointed.
8.    The total required pavement thickness shall be based on the Department of Main Road’s
      Pavement Design Manual using soaked CBR tests of the subgrade.
      The design pavement thickness, together with CBR test results shall be submitted to Council’s
      Chief Executive Officer (CEO) for approval prior to placement of pavement material.
9.    Suitable sediment control devices ("in pit” pollution control devices) shall be temporarily
      installed into the first existing external downstream stormwater structure.
      These devices are to be checked and cleaned on a regular basis and specifically after each
      rain event.
      These devices are to remain in place during the civil works and construction phases of the
      development.
      The location and type of device to be installed shall be established at the “pre start” meeting
      with Council’s Construction Technical Officer and shall be installed prior to the
      commencement of any works.
10.   Council’s Construction Technical Officer (ph 0410 512 505), shall be given seven (7) days’
      notice of intention to commence works to arrange a “pre start” meeting prior to the
      commencement of works.
                                                                                     Page 2 of 8

Used in these records

About this file

File size
60 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Decision Notice (Preliminary Approval) - 010.2009.00000768.001 [As Published].pdf · 60 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.