Job No. C06/023

January 2003 CONSTRUCTION HYDAULIC BUILDING SERVICES
ENGINEERS HYDRAULIC SERVICE CONNECTIONS

March 2003 LAND GRAPHICS
VEGETATION RETENTION PLAN

Statements Architect
Hydraulic Engineer
Landscape Architect

Various discussions and site inspections have followed to Overcome constraint issues relating to
development on the slope, the use of retaining walls, tree preservation and the impact of the upslope
boundary.

This report confirms the feasibility of the project and provides design and construction advice.

3.0 GEOTECHNICAL CONSIDERATIONS :

3.4 Stability of the Natural Slope

This is considered in the Golder report (July 2003) and shows the natural slopes on the site exceed that
of exposed (loose) sand. In other words, the natural slopes on Lot 3 have been enhanced by the
existing vegetation.

The average slope in the southern fifty percent of the site is 32 degrees steeping to the north to 36.5
degrees.

Golder makes reference to a central erosion or Slip feature (Page 3, Paragraph 1). This has been
marked on the site plan included as Figure 1. It has a back scarp angle greater than 40 degrees, and
side slopes steeper than the average site slope to Park Road, Correcting the contours gives a probable
slip or erosion depth of 1.5 metres.

3.2 Dune Support System :

There is common agreement that removal of vegetation would initiate a landslip in sand which could
effectively remove some of the top 3 metres of very loose sand. Nevertheless, the long term site
stability can be assured if any residential construction includes a dune support system as part of the

structure. &
On this site the dune support system has to:

a) Improve the general stope stability from contour 31m to 37m.

b} Remove the stability risk from the central erosion/slip feature.

3.3. Assumptions

3.3.1 From the Golder report, the average depth of very loose to loose and potentially unstable sand
is 2.8 to 3.0 metres.
3.3.2 The density of the sand is assumed to be as follows:
Very loose sand - 17kN/m?*
Loose sand - 17.5kNim?
3.3.3 The effective marginally safe slope on this site is equivalent to the natural vegetated slope of 32
degrees. The effective friction angle of the very loose to loose sand with the existing vegetation

cover and root system is assumed to be the same at 32 degrees, slighily greater than the angle
of repose of loose dune sand of 30 degrees.

00697 S Biggs MORRISON GEOTECHNIC

Used in these records

About this file

File size
3.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

08_0746 - Op Works - Stormwater [As Published].pdf · 3.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.