Site/building stability 23. Please provide comment from a suitably qualified geotechnical/structural engineer with regard to the site location and the possible affects of wave action and water inundation in a major storm event. Response: Correspondence prepared by Coffey Geotechnics is attached in Appendix H regarding the site location and possible affects of wave action and water inundation. Sewer 24. It is noted that a Council sewer main traverses the development site. The development plans show buildings located over the sewer. Provide plans showing buildings designed clear of the Council sewer within the development site, or a diversion of the sewer. A sewer diversion will require plans and longitudinal sections of the diverted sewer, the relationship to the proposed building and an easement over the sewer in accordance with the Noosa Plan - Planning Scheme Policy No. 6. Please note that No buildings or structures are permitted to be located within a sewer easement. Response: Plans prepared by Construction Hydraulic Building Service Engineers are attached in Appendix I showing a solution for diversion of the sewer, should the approved redevelopment of 33 Hastings Street not occur first, which would then result in the sewer in question becoming redundant. Stormwater 25. There is a discrepancy between the architectural plans and the stormwater management plans with regard to the location and extent of the retention and detention tanks. Please provide consistent plans. esponse: The attached architectural plans and stormwater management plans in Appendix I provide for a consistent location of the retention and detention tanks. Works 26. Confirm that separate male & female shower / change facilities and lockers will be provided for staff. Response: Separate male and female shower/change facilities will be provide for staff generally as detailed on drawing no. sk2000. 27. Demonstrate that the ramped public access path along the western boundary is compliant with the Disability Discrimination Act. Response: The ramped public access path along the western boundary will be compliant with the Disability Discrimination Act. Drawing no. sk2000 shows grades not exceeding 1:14 in accordance with the disability code. This matter is also subject to further detailed design and subsequent Operational Works application and will require Council assistance to make good the grades. wow
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/1787 - Response to Information Request [As Published]Related documentApplication case desk ↗
0019DFEA.001.pdfRelated documentPublic source context ↗
About this file
- File size
- 24.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.