Log in to see the plans as drawn7.1 Building Construction and Design Whilst Method 2 indicates lesser setybacks to be viable than Method 1, particularly to the SW, S and SE, precaution should be taken given the nature of the vegetation and isolation of the site. In this instance it is recommended that Method 1 be applied to building construction and associated setbacks. A minimum setback of 13m is required for BAL 29 to be viable, but is recommended that this setback is increased to closer to 20m to the west, north and east. Any other Class 10a structure built within 6m of the dwelling shall be constructed in accordance with this Standard. 7.2 Asset Protection Zones and Landscaping Figure 10. Components of an Asset Protection Zone (APZ) Asset protection zones provide the most strategically valuable defense against radiant heat and flame, and to a lesser extent embers. The function of the Inner Protection Area (IPA) is to distance the Asset from Flame and Radiant Heat. The Outer Protection Area (OPA) separates ground fuels from canopy fuels, causing canopy fires to collapse and become ground fires. The minimum 13m setback (agreed with Council and State) shall be constructed and maintained as IPA. The IPA should be maintained as free as possible of available fuel, through short mowing of grass and removal of fine flammable debris. Plants retained in or introduced into the IPA should be selected based on low combustibility, by virtue of high moisture content, low volatile oil content, high leaf mineral levels, large fleshy leaves, absence of shedding bark. Plant arrangement is just as important as low combustibility. Plants should be placed so as to not provide either vertical or horizontal connectedness of plant material. Appendix 1 provides examples of less hazardous plant species. Combustible vegetation shall not be allowed to come into contact with combustible parts of buildings. Trees shall not be allowed to directly overhang roof lines. The OPA should be maintained with low and minimal ground fuels, free of understorey or mid storey, and with separation of around 2 - 5m between tree canopies. In this instance the setback distance (agreed with Council and State) shall be constructed and maintained as IPA. Report compiled by Bushfire Risk Reducers for The Planning Place, July 2021 Page 18
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.