QC100259_Pomona Exchange_DD_Rev01-220630
Attached to the e-mail Operational Works Application OP"W22/0174 - DA Form 1 & 2 - Plans - 25 Railway Pde, Pomona.
1 2 3 4 5 6
SITE SIGNAGE ACCEPTANCE TESTING:
A A
1. PROVIDE PERSONNEL AND EQUIPMENT, MAKE REQUIRED
ONE OF EACH TO BE SUPPLIED PER SITE. TESTS, AND SUBMIT TEST REPORTS UPON COMPLETION
1
OF TESTS.
SITE SIGNAGE REQUIREMENTS 4
2. WHEN MATERIAL AND/OR WORKMANSHIP IS FOUND NOT TO
SIGN TO BE YELLOW BACKGROUND 3
COMPLY WITH THE SPECIFIED REQUIREMENTS, THE
WITH BLACK LETTERING
NONCOMPLYING ITEMS SHALL BE REMOVED FROM THE 2
ALUMINIUM MATERIAL REQUIRED
JOBSITE AND REPLACED WITH ITEMS COMPLYING WITH THE
SPECIFIED REQUIREMENTS PROMPTLY AFTER RECEIPT OF
ATTACHED WITH GALVANIZED HOG TIES OR
NOTICE OF SUCH NON-COMPLIANCE.
STAINLESS HARDWARE
B A. TEST PROCEDURES: B
STICKER TO BE ATTACHED TO BACK OF 1. ALL FEEDERS SHALL HAVE THEIR INSULATION TESTED AFTER
DISH VISIBLE FROM GATE AT NO HIGHER INSTALLATION, BUT BEFORE CONNECTION TO DEVICES. THE
THAN EYE HEIGHT CONDUCTORS SHALL TEST FREE FROM SHORT CIRCUITS AND
GROUNDS. TESTING SHALL BE FOR ONE MINUTE USING 1000V
DC. INVESTIGATE ANY VALUES LESS THAN 50 MEGOHMS.
2. PRIOR TO ENERGIZING CIRCUITRY, TEST WIRING DEVICES FOR
SITE ID: ___________ ELECTRICAL CONTINUITY AND PROPER POLARITY
CONNECTIONS. 5
SITE SIGNAGE REQUIREMENTS
1
FOR ACCESS OR EMERGENCIES 2 ENGRAVED SIGNS
C ADHESIVE BACKED 3. MEASURE AND RECORD VOLTAGES BETWEEN PHASES AND C
CONTACT: 75mm x 150mm BETWEEN PHASE WIRES AND NEUTRALS. SUBMIT A REPORT
SERVICE ASSURANCE CENTER OF MAXIMUM AND MINIMUM VOLTAGES.
1800 842 728 END OF SECTION
SITE ID: ___________
END OF SPECIFICATION ADDRESS:_____________
________________________
FOR ACCESS OR EMERGENCIES
CONTACT:
SERVICE ASSURANCE CENTER
1800 842 728
FIP01 SITE SIGNAGE REQUIREMENTS
ENGRAVED SIGNS
3 ADHESIVE BACKED
D FIBER INTERFACE PANEL 75mm x 150mm
D
SERVICE FROM FIBER DEMARC SITE ID: ___________ 5
SERVICE TO EQUIPMENT CABINET ADDRESS:_____________
________________________ SITE SIGNAGE REQUIREMENTS
ALUMINIUM MATERIAL REQUIRED
200mm x 250mm
FOR ACCESS OR EMERGENCIES
CONTACT:
ATTACHED WITH GALVANIZED
MDP01 SERVICE ASSURANCE CENTER HOG TIES OR STAINLESS
SITE SIGNAGE REQUIREMENTS
1800 842 728 HARDWARE
ENGRAVED SIGNS
E MAIN DISTRIBUTION PANEL 4 ADHESIVE BACKED E
240v, 1 PH 75mm x 150mm
FED FROM TELCO SUPPLY
FEEDING EQUIPMENT CABINET
TO BE READ IN CONJUNCTION WITH SHEETS S0, S1, S1-1 & S3. FOR CONSTRUCTION
ORDER DRAWN CHKD AMENDMENT EXAM APPD DATE ISS
183929 JM MF FOR CONSTRUCTION - SP30092467WO015DOWN - SATELLITE RC PG 17.06.22 0.1
SATELLITE ACCESS NODE SITE 183929
POMONA EXCHANGE
F SITE SPECIFIC NOTES - SHEET 2 OF 2 F
25 RAILWAY PARADE, POMONA, QLD 4568
DWG SHT S0-1
C Telstra Corporation Limited ABN 33 051 775 556 All rights reserved. NO. QC100259 NO. .
1 2 3 4 5 Cad file: QC100259.dwg A3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.