QC100259_Pomona Exchange_DD_Rev01-220630

Attached to the e-mail Operational Works Application OP"W22/0174 - DA Form 1 & 2 - Plans - 25 Railway Pde, Pomona.

of 20

Page text shows just the words. Original shows the document exactly as it was published.

      1                                              2                                3                                                     4                                                     5                                                 6

    SITE SPECIFIC NOTES                                                                                                                                                                                SITE REFERENCE DETAILS
A                                                                                                                                                                                             OCCUPIER                   SITE NAME                  SITE CODE A
    EQUIPMENT PLATFORM                                      WORKPLACE HEALTH & SAFETY
                                                                                                                                                                                                      TELSTRA          POMONA EXCHANGE                  183929
    TYPE: PROPOSED STEEL 'MOON' PLATFORM.                   ASBESTOS CONTAINING MATERIALS WERE IDENTIFIED
    SIZE (mm): APPROX. 915 x 1200mm.                        DURING INSPECTION & DESIGN STAGES, SUBSEQUENTLY
    BASE TYPE: STEEL BASE PLATE                             CONFIRMED BY REVIEW OF THE TELSTRA REGISTER OF
                                                            ASBESTOS MATERIALS. ALL NECESSARY CONTROLS WILL                                                                                 SERVICES LEGEND
                                                            NEED TO BE IN PLACE DURING THE CONSTRUCTION PHASE
    EARTHING                                                TO CONTROL THIS IDENTIFIED HAZARD.                                                                                                                                OPTICAL FIBRE ABOVE GROUND
    PROPOSED SAN EQUIPMENT AND COMPOUND SHALL BE                                                                                                                                                                              OPTICAL FIBRE BELOW GROUND
    EARTHED AS PER SAN AND TELSTRA REQUIREMENTS.            GENERAL NOTES                                                                                                                                                     ABOVE GROUND ELECTRICAL SUPPLY
                                                                                                                                                                                                                              BELOW GROUND ELECTRICAL SUPPLY
B   REFER TO SHEET G4 FOR SITE SPECIFIC EARTHING            1. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS SPECIFIED
                                                                                                                                                                                                                                                             B
                                                                                                                                                                                                                              GAS SUPPLY BELOW GROUND
    DETAILS.                                                   OTHERWISE.                                                                                                                                                     HIGH VOLTAGE ELECTRICAL SUPPLY
                                                                                                                                                                                                                              WATER SUPPLY ABOVE GROUND
                                                            2. ALL CABLES TO BE BIRD PROOFED AT TIME OF ACTIVE BUILD. BIRD PROOFING
    ENVIRONMENTAL ISSUES                                       SOLUTION TO BE PROVIDED BY VIASAT INCLUDING MATERIALS AS FREE ISSUE                                                                                            WATER SUPPLY BELOW GROUND
                                                               WITH ACTIVE KIT.                                                                                                                                               SEWER LINE
    REFER TO ENVIRONMENTAL RISK ASSESSMENT
    CHECKLIST 018422f10 INCLUDE ANY ANIMALS:                                                                                                                                                                                  STORM WATER
                                                            3. SERVICES, WHERE SHOWN ARE INDICATIVELY ONLY. LOCATION OF                                                                                                       ABOVE GROUND FEEDER CABLES
    NESTING BIRDS: OSPREY ETC.
                                                               ALL RELEVANT EXISTING SERVICES SHALL BE IDENTIFIED AND
    DANGEROUS SNAKES, WASPS & SPIDERS ETC.                                                                                                                                                                                    BELOW GROUND FEEDER CABLES
                                                               CONFIRMED PRIOR TO COMMENCING WORK. THE CONTRACTOR TO
    MENACING CATTLE ETC.                                                                                                                                                                                                      EARTH STRAP
                                                               LIAISE WITH RELEVANT AUTHORITIES FOR DIRECTIONS AND
                                                               PERMITS REQUIRED.                                                                                                                                              ABOVE GROUND 16mm² EARTH
C                                                                                                                                                                                                                                                              C
    POWER SUPPLY                                               DIAL BEFORE YOU DIG 1100.                                                                                                                                      BELOW GROUND 35mm² EARTH
                                                                                                                                                                                                                              BELOW GEOTEXTILE MAT,
    32A/1P SUPPLY SHALL BE TAKEN FROM PROPOSED              4. CONSTRUCTORS ARE TO BE AWARE OF TELSTRA DOCUMENT                                                                                                               35mm² EARTH IN FLEX GREY CONDUIT
    WALL MOUNTED EXTERNAL SAN DISTRIBUTION BOARD               007338-C8-11 AND IN PARTICULAR CLAUSE 7.3 & 10.3 WHICH
    TO BE INSTALLED BY TELEPOWER. REFER TO SHEET               DESCRIBES REQUIREMENTS PERSONNEL MUST UNDERTAKE IN
    S1 AND S1-1 FOR PROPOSED LOCATION AND SHEET E2             RESPECT TO ASBESTOS MANAGEMENT AT TELSTRA FACILITIES.
                                                                                                                                                                                              1           EXISTING TELSTRA ANTENNA SECTOR
    FOR AC POWER DETAILS.
                                                            5. PROPRIETARY PRODUCTS SHALL BE INSTALLED IN ACCORDANCE WITH                                                                    A1
    DIAL 1100 BEFORE YOU DIG.                                  MANUFACTURERS SPECIFICATIONS.
                                                                                                                                                                                              1           PROPOSED TELSTRA ANTENNA SECTOR
                                                            6. COMPOUND SHALL BE ORIENTATED TO SUIT SITE-SPECIFIC REQUIREMENTS &
    PROPERTY SIGNAGE                                           ANTENNA AZIMUTH. REFER TO SITE-SPECIFIC COMPOUND LAYOUT DRAWING.
                                                                                                                                                                                             A1
D                                                                                                                                                                                                                                                                       D
    SPECIFY PROPERTY SIGNAGE AS PER DOCUMENT 017866A12.
                                                            7. COMPOUND SHALL BE STRIPPED OF ALL VEGETATION & TOPSOIL. COMPOUND
    SITE NAME: BRANDED SITE IDENTIFICATION REGULAR (BSr).
                                                               SHALL BE FINISHED WITH A LAYER OF GEOTEXTILE UNDERLYING MIN. 100mm
    TELSTRA S/I NUMBER 187/00929.
                                                               LAYER OF SITE GRAVEL.
    JABAC PART NUMBER TFMS929-M.
                                                            8. SITE GRAVEL:
    SITE ACCESS                                             VICTORIA: 100mm COMPACTED
                                                            THICKNESS SIZE 20 CLASS 3 FCR
    VIA RAILWAY PARADE
    REFER TO SHEET S1                                       QLD: 100mm COMPACTED THICKNESS
    SITE S.A.C. TO ADVISE C.D.C. LOCATION DETAILS.          TYPE 2.3 ROADBASE
E                                                                                                                                                                                                                                                                       E
                                                            NSW/ACT: 100mm COMPACTED THICKNESS
    SITE SIGNAGE                                            DGS20 ROADBASE
    ALL EME SIGNAGE IS REFERENCED ON DRAWINGS S1 & S3.
    REFER TO DOCUMENT 005486 FOR DETAILS.                   CYCLONIC SITES
                                                                                                                                                                                                                 FOR CONSTRUCTION
                                                                                                         TO BE READ IN CONJUNCTION WITH SHEETS S0-1, S1, S1-1 & S3.
                                                            REFER SHEET T2-2 FOR SPECIFIC REQUIREMENTS ORDER DRAWN            CHKD                   AMENDMENT                      EXAM APPD DATE ISS
                                                            FOR SITES IN NOMINATED CYCLONIC WIND ZONES. 183929 JM             MF FOR CONSTRUCTION - SP30092467WO015DOWN - SATELLITE RC PG 17.06.22 0.1
                                                                                                                                                                                                                SATELLITE ACCESS NODE SITE 183929
                                                                     COMPLIANCE BOX                                                                                                                                     POMONA EXCHANGE
                                                                   COMPLETED AS PER DESIGN
F                                                                                                                                                                                                                       SITE SPECIFIC NOTES - SHEET 1 OF 2              F
                                                                   ALTERATIONS IN RED                                                                                                                                 25 RAILWAY PARADE, POMONA, QLD 4568
                                                                   NAME (PRINT)
                                                                                                                                                                                                                DWG                                     SHT       S0
                                                                   SIGNATURE                DATE
                                                                                                                    C Telstra Corporation Limited ABN 33 051 775 556 All rights reserved.                       NO.      QC100259                       NO.   .
      1                                              2                                3                                                     4                                                     5                        Cad file: QC100259.dwg                      A3
Log in to download the original file

QC100259_Pomona Exchange_DD_Rev01-220630.pdf · 2.9 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.