Appendix 4 - accoustic report · MCU19/0117
Attached to the e-mail MCU19/0117 - Response to Information Request - Visitor Accommodation Type 3 – Rural (Guest House and Private Lagoon).
Mark Bain Constructions Pty Ltd Environmental Noise Level Impact Assessment for Proposed Wave Lagoon, 500/90 Beach Road, Noosa North Shore Page 7 of 16 With respect to the above night-time ambient noise levels, the Acoustic Quality Objectives for the night-time are: o 35 dB(A) LAeq,adj,1H; o 40 dB(A) LA10,adj,1H; and o 45 dB(A) LA1,adj,1H. The current average night-time ambient noise levels exceed this noise limit criteria by 6.5 dB(A) LAeq,1H, 6.6 dB(A) LA1,1H and 1.8 dB(A) LA10,1H. This difference between the current average night-time ambient noise levels and the noise limits should ensure that any noise from the proposed wave lagoon will be either inaudible or only just barely audible at the closest residential. Based on the above the noise limits are: pumps and blowers: o daytime (0700 to 1900 hours): 41 + 5 = 46 dB(A) LAeq,adj,T; o evening (1900 to 2200 hours): 39 + 3 = 42 dB(A) LAeq,adj,T; o night-time (2200 to 0700 hours): inaudible = ≤ 30 dB(A) LAeq,adj,T; people noise: o daytime and evening: 50 dB(A) LAeq,adj,1H; 55 dB(A) LA10,adj,1H; and 65 dB(A) LA1,adj,1H; o night-time: 35 dB(A) LAeq,adj,1H; 40 dB(A) LA10,adj,1H; and 45 dB(A) LA1,adj,1H; SOURCE NOISE LEVELS Typical source noise levels are: Steady state sources: blower (total of 8): o discharge air: 119 dB(A) LWA each; o casing radiated: 88 dB(A) LWA; pump (assumed 2 of): 90 dB(A) LWA; Time varying noise source: people: 62 dB(A) LAeq,adj,T, 70 dB(A) LA1,adj,T and 65 dB(A) LA10,adj,T @ 10 m. The blower source noise data was extracted from a report prepared for a wave lagon (believed to be of similar size) at Palm Springs, California. The quoted blower is manufactured by Chicago Blower Corporation, model 6105SW. It is believed that the blowers and pumps will be located under-ground/built into an embankment and contained within a concrete structure (or equivalent) – concrete floor, walls and roof. It has been further assumed that the concrete structure will have a minimum Rw 50 (noise reduction of 45 dB(A)). David Moore & Associates Pty Ltd Our reference: R19099/D3453/Rev.0/21.01.2020
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix 4 - accoustic report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.6 MB (small file)
- File type
No other editions are linked here.