Appendix 4 - accoustic report · MCU19/0117
Attached to the e-mail MCU19/0117 - Response to Information Request - Visitor Accommodation Type 3 – Rural (Guest House and Private Lagoon).
Mark Bain Constructions Pty Ltd Environmental Noise Level Impact Assessment for Proposed Wave Lagoon, 500/90 Beach Road, Noosa North Shore Page 8 of 16 NOISE LEVEL IMPACT The concrete structure containing the blowers and pumps is proposed to be located adjacent to the western corner of the wave lagoon, which has a separation distance of approximately: 160 metres to the closest residence to the west: 700 metres from the closest residence to the south. Compliance with the noise limits at the closest residence to the west will also result in noise limit compliance at all other nearby residences. Whilst it is most likely that the wave lagoon will only be used during daylight hours, this could be as early as 0500 hours in the summer. There is also a small likelihood that the wave lagoon could be used during the evening, up to 2200 hours. It has been assumed that the generation of waves could occur at any time from 0500 hours to 2200 hours. Steady State Noise Sources At the closest residence to the west the noise of the plant and equipment, which will all be located inside a concrete structure (or equivalent) the noise level impact would be: blower discharge: 119 LWA + 9 (total of eight blowers) – 52 (distance of 160m) – 45 (concrete structure) – 7 (ground) = 24 dB(A) LAeq,adj,T; 122 LWA + 9 – 52 – 45 – 7 = 27 dB(A) LA1,adj,T; 120 LWA + 9 – 52 – 45 – 7 = 25 dB(A) LA10,adj,T; blower radiated: 88 LWA + 9 (total of eight blowers) – 52 (distance of 160m) – 45 (concrete structure) – 7 (ground) = -7 dB(A) LAeq,adj,T; 91 LWA + 9 – 52 – 45 – 7 = -4 dB(A) LA1,adj,T; 89 LWA + 9 – 52 – 45 – 7 = -6 dB(A) LA10,adj,T; pumps: 90 dB(A) LWA + 3 (two pumps) – 52 (distance of 160m) – 45 (concrete structure) – 7 (ground) = -11 dB(A) LAeq,adj,T; 93 dB(A) LWA + 3 – 52 – 45 – 7 = -8 dB(A) LA1,adj,T; 91 dB(A) LWA + 3 – 52 – 45 – 7 = -10 dB(A) LA10,adj,T; combined: 24 dB(A) LAeq,adj,T, 27 dB(A) LA1,adj,T and 25 dB(A) LA10,adj,T. The combined noise level of all of the eight blowers and two pumps comply with both the default noise standard for pumps, as well as the acoustic quality objectives. Time Varying Noise Source The most likely time varying noise source is people noise from the wave lagoon, with a separation distance of approximately 180 metres to the closest residence to the west. At this closest residence to the west the noise level impact of the time varying noise source will be: people: 62 dB(A) LAeq,adj,1H @ 10m – 25 (distance of 55m) – 7 (ground) = 30 dB(A) LAeq,adj,1H; 70 dB(A) LA1,adj,1H @ 10m – 25 – 7 = 38 dB(A) LA1,adj,1H; 65 dB(A) LA10,adj,1H @ 10m – 25 – 7 = 33 dB(A) LA10,adj,1H; The above people noise complies with the acoustic quality objective criteria for the daytime, evening and night-time, with no additional noise control measures required. David Moore & Associates Pty Ltd Our reference: R19099/D3453/Rev.0/21.01.2020
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix 4 - accoustic report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.6 MB (small file)
- File type
No other editions are linked here.