Council archive · source document
OPW11/0023 Development Application part 2 of 2 Planning Report and Plans 178 Eumundi Noosa Road Noosaville
Plans and drawings: the text below has words only, no drawings.
Very large file (70.0 MB): may take a few minutes to open.
BUNNINGS WAREHOUSE, NOOSAVILLE
SURFACE WATER MANAGEMENT PLAN
(40:^ Cardna
2. WATER QUANTITY
2.1 Rainfall data
Historical rainfall intensities were calculated with AUS-IFD software, employing methods
detailed in the Institute of Engineers Australia's 1987 Australian Rainfall & Runoff (ARR).
1 The parameters used in the software are listed in Table 1 below.
Table 1 Rainfall Parameters for Rockhampton
wy uw,nuau nUwnaIuca,,nnnnn,
2 year 1 hour 50.0 50 year 1 hour 93.64
2 year 12 hour 10.69 50 year 12 hour 23.84
2 year 72 hour 3.38 50 year 72 hour 9.26
Geographical Factors
Skewness G 0 F2 4.23 F50 17.85
The AUS-IFD software produces a table of rainfall intensities for a range of storm durations,
and this information was entered as a series of design storms to the RAFTS database.
Zone 3 temporal patterns were applied to the data according to the ARR standard.
2.2 RAFTS Model Setup
The site was divided into several subcatchments according to lot position, slope and
direction of fall. These are shown schematically on Figure 1 and in plan on Figure 4. In
order to mitigate against the potential increase in stormwater runoff following development,
the existing situation was also modelled in order to establish a baseline.
Slopes in the existing situation were derived from information provided on the surveyor's
drawings, and from contours, and slopes for the proposed situation were estimated. These
were later adapted to achieve calibration, as described in the following section.
Pervious and impervious areas were calculated assuming that the site is completely
pervious in its existing state, and completely impervious following development (except for
the bioretention strips and landscaping, which are assumed to be completely pervious).
The model parameters are listed in Table 2 below.
Table 2 RAFTS Model: Area and Slope
Existing Proposed Existing Proposed
Node Area (ha)
Slope (%) Slope (%) Mannings Mannings
Car park 1.1190 4 2 0.07 0.025
Bioretention 0.1507 4 2 0.07 0.07
Roofs 0.7884 4 30 0.07 0.025
Hardstand 0.2064 4 2 0.07 0.025
Landscape 0.2011 4 2 0.07 0.05
Each node in RAFTS is also assigned rainfall losses: for pervious areas, initial loss is zero,
and continuing loss is 2.5mm. For impervious areas both losses were set to zero.
Bunnings Warehouse Version 1 15 December 2006
j \3501-54\lAP\SWMP doc Commercial in Confidence Page 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
OPW11/0023 Development Application part 2 of 2 Planning Report and Plans 178 Eumundi Noosa Road NoosavilleRelated documentApplication case desk ↗
About this file
- File size
- 70.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.