D
OVF
HW
EX-
ree
G
TL-07
t
as per manufacturer's recommendations fall New New planter New planter
U203 terrace
ick s
HYD
Sc
Box gutter
B5
Br las
s
and landscape architect's details Roof
L-
OC
G
(new tiled finish) T.O.W. EX-COL
BA
fa
DP/OVF Void 2° RL 6.080 FFL 5.630
SHS
TL-07 TL-07 PWD
BAL-01
TL-07 ll
U204 Void WT
fa
OC Landing
Roof 5 OVF CBR 1
17 D
ll
BA FL ES TL-07a
L-
B5 CBR SETOUT POINT
0
R EX-COL Gate
FH
OVF EX-COL FL EX-DP J
0
FL
1:4
EX-DP EX-COL EX-COL FL FL EX-DP Refuse N-DP N-DP I GP
New Roof
Planter GP GP
TL-07 SHS
EX-DP EX-COL BAL-01 Suite 2,
36
D
5°
EX-DP in wall Box G.
Existing EX- EX-DP EX-COL TL-07 Male
FL to wall FL DP 1:40 EX-COL BAL- TL-07a 0 Cnr Gard
FL DP/OVF Lift Core 01 Walkway
New Roof
TL-07 02
A
below Roof 6
EX-DP (new tiled finish) EX-DP BAL-04 BAL-ST3 Alexand
CBR
2°
U202 terrace CBR FL
PO Box
O
(new tiled finish)
(new tiled finish) EX-DP EX-COL N-DP KEX
FL FL EX- EX-COL
FHR
Walkway
BAL-ST1
EX-COL
BAL-ST1
DP EX-COL
P 07 54
R
New Roof
TL-07 Blade wall below FL FL Existing
GD fall
U203
BAL-ST1
BAL-ST1
FL New concrete N-COL
admin@
2°
Concealed fascia gutter Lift Core 02 infill to existing
Fascia gutter
N-RWO KIN EX-COL
Roof 1 CBR FL planter over
BAL-B1
EX-COL
K
EX-COL
4825
FL DP and OVF in wall New Roof blockwall
D CBR Existing Gravel Existing
fall Barrier to divert 3°
R
FL Flashing to wall under stair Fire Stair 01 FL Fire Stair 02 SUNCOAST RESORT BUSINESS CENTRE
New Roof
DP/OVF water off roof
EX-DP in wall New roof over entry court Roof 9 Gravel SUITE 2 CNR GARDAK ST & SURF RD
A
N-
2°
Line of glazed N-DP + N-DP
316 S.S RWO
FL and car park entry. Provide Custom P.C. alum. sun Modify existing sail awning ALEXANDRA HEADLAND Qld 4572
U201 terrace wall under spreader FL steel frame structure for
fire separation measures as hood box surround to PO BOX 6232 MAROOCHYDORE BC Qld 4558
P
Box Gutter shown dotted
(new tiled finish) part of NCC requirements window opening fixing to top of wall PH : 07 5443 5028 FAX:07 5479 2380
6600 New planter area with new
FL fall
TL-07
soil under. Provide new ABN 23 123 917 724
Connect floor waste to
GD U202 existing DP in Providore New powdercoated proprietary type waterproof EMAIL: [email protected]
BAL-B1
aluminium screen fixed tanking membrane to slab
to stair / slab edge as per manufacturer's
Exis. Fall
FL project
recommendations and
landscape architect's details PROPOSED ALTERATIONS &
New Roof
ADDITIONS TO EXISTING
Exis. Fall
TL-07
EX-DP
2°
FL
Provide 50 - 75 mm Tile OC
Raised terrace under
RESORT BUILDING
16965
Setout 316 S.S
contrasting nosing strip to all Point
OVF Box gutter DP/OVF for
stair treads as per AS1428.1
Roof 4 FL DP/OVF Existing Tenancies NETANYA RESORT
CBR Concealed fascia gutter
U201 Existing
EX-DP
FL at
Fire Stair 03 Feature powdercoated
aluminium placards to 75 HASTINGS STREET
EX-DP FL existing blockwork wall
in wall DP/OVF
NOOSA HEADS
FL 316 S.S Box gutter
485 DP/OVF
CBR drawing
FL FL
NEW WORKS - FIRST FLOOR
fascia gutter
Line of feature seating
Concealed
Roof 2
316 S.S
New Roof Roof 3 and planter below
FL FL
2° CBR
New Roof
FL
FL
3°
-
Select powdercoated
alum. 'Alspec' sun hood New 100 x 25 powderocated
New roof over
outdoor terrace
GENERALLY IN ACCORDANCE date 11/08/2021 drawn JP
AS SHOWN
scale @A1
surround to window aluminium screen fixed to wall APPROVED PLAN
3455
SD20.01 revision J
/ slab edge. drawing no. 19021
New roof over shopfront entries,
supported on cantilevered FL
B MCU13/.0081.02
400
structure and blade walls under NOOSA COUNCIL
Copyright of this document remains the exclusive
13 SEPTEMBER 2021
N
property of SPROUT ARCHITECTS PTY LTD
ABN 23 123 917 724.
LEVEL 1 Scale 1:100
- Contractors are to verify all dimensions and levels on
site prior to commencing. Report all discrepancies to
the Architect. Use figured dimensions in preference
Scale 1:100 0 5 10 20 to scaled.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans - MCU13-0081.02.pdfRelated documentApplication case desk ↗
About this file
- File size
- 16.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.