1.4 Performance Criteria
The adopted for the development with respect to the management of overland flow:
• Overland Flow:
– Development site and buildings to achieve appropriate freeboard above the 1% (2100) AEP flood level.
– No external impacts to adjoining properties.
– Footpath at end of Serenity Close achieves a depth x velocity project less than 0.4m2/s and depth less than 0.25m in 1% (2100) AEP.
– Assessment of severe storm (i.e. 1% (2100) AEP event with 100% blocked pipes).