App B - Effluent Information

of 16

Page text read automatically using OCR, there may be inaccuracies

5.1 AES Infiltration Bed Design.            Advanced Enviro-Septic System

The AES Bed Design is to be a gravity fed, below ground system. See system design drawings page 6.

The total bed base required is 36m2 (9m x 4m). Bed is to be installed as shown on the site plan. See drawings page 6 for bed
profile. A minimum 4m setback is required to any tree.

The entire bed base it to be ripped 250mm parallel to the AES pipes and gypsum applied at 1kg per m2.

Coarse washed sand will be referred to as “system sand” and must meet the specifications of the system manufacturer.
System sand will need to be placed around AES pipework and for the infiltration area as shown on the attached drawings.

System pipe bed dimensions (Area A) are 6.6m x 1.35m and a total minimum sand depth of 750mm. 300mm of course washed
sand is to be spread to form a base and 2 rows of 2 lengths of AES pipes installed as per the attached drawings.

A further infiltration area (Area B) is to be constructed around and below the pipe bed as per the site drawings and a minimum of
150mm system sand to be spread over the entire infiltration area.

Pipes are to be covered by a minimum of 150mm of system sand. A further 150mm of site soil is to be mounded over the sand to
prevent surface water entering the bed. After all settlement the AES Bed is to have a minimum 150mm cover of site soil.

Beds are to be constructed in accordance with the AES Design and Installation Manual and all plumbing works in accordance with
the QPW code. All site work is to be carried out by a licenced plumber and all AES horizontal pipes layed with the aid of a laser
or dumpy level to ensure absolute compliance with the manufacturers installation guidelines. This is critical for correct operation.

Oxygen Demand Vents are to be installed as per the AES Design & Installation Manual. The high vent (100mm - on the studio)
must be a minimum of 3m higher than the AES low vent and provide unrestricted air flow through the entire system.

Two Inspection Ports are to be installed, one in the centre of the pipe bed and another at the furthest point from the influent to AES
Pipes. See Installation Instructions Appendix A - page 11.

Care must be exercised to prevent machinery access on the AES bed during and after construction.




      6.0 Setback Regulations:

                                                                                  Secondary          Advanced Secondary
        Recommended Separations Distances - Surface Irrigation
                                                                                  Effluent                Effluent
          Dwellings & recreation areas                                                10m                   10m
          Water edge of swimming pools                                                 6m                    6m
          Property boundaries, paths & walkways                                    2m uphill             2m uphill
                                                                                   4m down hill          4m down hill
          Top of bank of permanent water course, creek, lake, waterway etc.             30m                 10m

          Bore or Dam for domestic or stock use                                         30m                   10m
          Vertical depth of seasonal water table                                       0.6m                   0.3m
          In ground potable water tank. Note some authorities require 15m               6m                     6m
          Sub-Surface Irrigation same as above except for;
         Dwelling & recreation areas                                                    4m                     4m

     NOTE: The local government authority may upon considering the public health and environmental risks
     reduce or increase the distances in the above table.
    Regards,




    Lance Picton jp.
    Site Classifier
    QBCC Lic: 1049265
                                                                                     C Copyright Lance Picton 2023 design & content.   4/11

Log in to download the original (App B - Effluent Information.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.