App B - Effluent Information

of 16

Page text read automatically using OCR, there may be inaccuracies

5/11


[OCR of page images]
 

 

’ ADVANCED
J ENVIRO-SEPTIC Advanced Enviro-septic Design Calculator v9.0 ©

“Always The First Option”
AES The World Leader in Passive Solutions ©

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Site Address 122 Musa Vale Rd Cooroy. State QLD Post Code
Client Name Jody Austin Date of Site Visit
Designers Biowater Design Pty Ltd Desaners Ph SO ieemadond “ence Meee
Lic Plumber TBA Pramber Ph TBA Plumb Drainer Le TBA
Council Area Noosa Designers AES 1 Date 21.04.2023,
This Calculator is a guide only, receiving soil classification, surface water, water tables and all other site constraints addressed by the qualified designer.
Enter AES L/m loading rate, "30" for ADV Secondary or "38" Secondary 30 >> This design is for an ADVANCED SECONDARY system
Is this anew installation Y or N Y >> Minimun single vent size is 80mm or 2 x 50mm house vents
Number of Bedrooms 1 >> This is not used in ANY Calculation. If not known use N/A or 0.
Number of persons 3 >> A septic tank outlet filter is NOT RECOMMENDED
Daily Design Flow Allowance Litre/Person/Day 120
Number of rows required to suit site constraints 2 >> The maximum length of a single AES pipe run is 30m or 10 PIPES
Infiltration Soil Category from site/soil evaluation. CATEGORY 5 >> Catagory may require design considerations. Ref AS1547
Design Loading Rate based on site & soil evaluation DLR (mm/day) 10 >> Soil conditioning may be necessary. Ref AS1547 & Comments.
Bore log depth below system Basal area 1.5m >> Min depth 1.5m. Check water table/restrictive layer
Is this design a GRAVITY system with no outlet filter? Y or N Y >> GRAVITY. A House Vent & LOW VENT required on this system

 

 

 

PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES

 

 

COMMENTS :-" The outcome must be important to everyone. "

- Ripping of receiving surface required in clay soil structures in Cat 4

 

In addition refer to AS 1547. Always excavate & rip parallel to the site slope/AES pipe.
- Specialist soils advice & special design techniques will be required for clay dominated soil having dispersive or shrink/swell behaviour. Refer AS1547
- Designers need to be familar with special requirements of Local Authorities. ie - Minimum falls from Septic tank outlets to Land application areas ete

- Plumbers are reminded good construction techniques as per AS1547 are especilly important in these soil types. Refer AS1547 & AES installation Instructions

AES System Calculator Outcomes AES dimensions

 

 

 

 

 

 

 

 

 

 

 

 

Total System load - litres /day (Q). 360 Wd AES System Extension Area
Min Length of AES pipe rows to treat loading 6.25 Im Length:(L)
Number of FULL AES Pipe lengths per row 2 Iths Width:(W)

‘Sand Depth

Total Capacity of AES System pipe in Litres 848 ltr, : 0.75m 0.15m

‘Area m2 8.9 m2 27.4 m*2
USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER Y) | | >>stope percentage must be 0% & infiltration footprint must be level for this design
IF YOU WISH TO USE A TRENCH EXTENSION DESIGN OPTION ENTER "Y" Y Enter Custom Width in metre 4
AES INFILTRATION FOOT PRINT AREA- L=Q/(DLR x W) Length Width Minimum AES foot print required
The length & width of excavation required for this design is >> 9.00m x 400m = 36.0 m2 total

 

 

 

AES pipes are best centered in the trench parallel to the site slope

 

 

 

   

 

AES System Bill of Materials. Chankar Environmental Use Only

AES-PIPE AES 3 metre Lengths required 4 Iths

|AESC AES Couplings required 2 ea

|AESO. AES Offset adaptors 4 ea a ADVANCED on

ENVIRO-SEPTIC

AESODV AES Oxygen demand vent 1 ea “Nature's Wastewater Solutions”

AES-IPB AES 100mm Inspection point base 2 ea

TD Kit 4 4 Hole Distribution Box Kit ea

TD Kit 7 7 Hole Distribution Box Kit ea Digitally signed by Steve Dennis

VS43-4 Sweet Air Filter VS43-4 ea DN: cn=Steve Dennis, o=Chankar

AES DESO Double Offset Adaptors ea Enviromental, ou=Design Review, |
email=steve@enviro-

TOTAL SYSTEM SAND REQUIRED (Estimate Only) 13 m3 .
septic.com.au, c=US
Please email your AES Calculator (EXCEL FORMAT), Site Layout & AES Design to Date: 2023.04.22 17:30:13 +10'00'
designreview @enviro-septic. comau— designreview @enviro-septic com au

 

[> The AES Calculator is a design aid to allow checking of the AES components, configuration and is a guide only. Site and soil conditions referencing AS1547 are
calculated and designed by a Qualified Wastewater Designer.
|> Chankar Environmental accepts no responsibility for the soil evaluation, loading calculations or DLR entered by the designer for this calculator.
|> AES pipes can be cut to length on site. They are supplied in 3 meter lengths only.
> AES ONLY supply AES components as detailed in the Bill of Materials.
> SEPTIC Tank & other components including SAND will need to be sourced from other suppliers. Refer to our WEBSITE www.enviro-septic.com.au OR 07 5474 4055
AES-Design-V9.0-Calculator © Copy Right - Chankar Environmental Pty Ltd 20/1/2022

 

 

 

5/11

 

 

Log in to download the original (App B - Effluent Information.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.