Council archive · source document
Compiled Approved Plans MCU17 0004 04 & REC17 0002.04 · MCU17/0004.04
Plans and drawings: the text below has words only, no drawings.
Very large file (10.8 MB): may take a few minutes to open.
© COPYRIG HT | All rights reserved. This work is copyright and canot be
reproduced or use figured dimensionsions.
DO NOT SCALE check all dim ensions on site before fabrication or set out.
DO NOT COPY in any form or by me ans (graphic, electronic or mechanical,
includin g photocopying) without the written permision of Mercury Design.
EXTERIOR FINISHES LEGEND
RL 9660 8m Above Existing Ground Line
CODE DESCRIPTION
Colorbond Custom Orb roof sheeting ECL-01 Hardies Scyon Linea 180mm, painted
on trusses at 900crs ECL-02 Block with 10mm[nom] smooth cement
ERO-02
render finish + painted
Colorbond fascia and gutter, to
selection, fixed to manuf's specs ECL-03 Hardietex FC with smooth render finish +
Roof painted
8430 EFL-01 Metal roof flashing to match roof
Privacy screen with 25% max visibilty
EJO-01 EJO-01 Aluminium joinery, powder coated
up to 1500mm min above FFL, refer
EJO-02 Aluminium joinery, powder coated
2600
detail
EJO-03 EJO-03 Aluminium joinery, powder coated
Hardies Scyon Linea 180mm FC ERO-02 Colorbond Custom Orb roof sheeting
8000 at ridge
cladding fixed to manuf's specs ESS-01 316 Marine Grade Stainless Steel
above EGL
ECL -01
First Floor ETP-01 HWD timber post, painted
5830
ETP-01
Sectional overhead door as per
2750
selection
Ground Floor
2700
Flood Level EJO-02
2400
Existing Ground Line
HOUSE 2 NORTH ELEVATION
1 Scale: 1 : 100
8m Above Existing Ground Line
-
Colorbond Custom Orb roof sheeting
on trusses at 900crs NOOSA COUNCIL
Roof
8430
ERO-02 APPROVED PLAN
MCU17/0004.01,
OPW17/0005.01 & REC17/0002
ECL -01 EJO-03
2600
Hardies Scyon Linea 180mm FC
cladding fixed to manuf's specs
4 MAR 2019
ECL -02
First Floor
5830 SITE
46-48 ELIZABETH STREET
140x140 Dressed HWD timber posts, NOOSAVILLE, QLD 4566
paint finish to selection PROJECT
TOWNHOUSE DEVELOPMENT
2750
UNIT 4 GARAGE M/B CLIENT
46 ELIZABETH Pty Ltd
DRAWING TITLE
HOUSE 2 ELEVATIONS
Ground Floor
2700 DESIGNED SCALE
B.D.H. 1 : 100
CHECKED STAGE - ISSUE
B.D.H. BA - C
Existing Ground Line DRAWN DATE
MJ 26.02.2019
HOUSE 2 EAST ELEVATION PROJECT No. PAGE No.
2 Scale: 1 : 100 0 1
18070
2 3
D19 OF 84
4 5m
1: 100 1 3 0 0 1 3 3 9 1 7
[email protected]
PRELIMINARY - NOT FOR CONSTRUCTION Q.B.C.C. 1029724
26/02/2019 11: 23: 46 AM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Compiled Approved Plans MCU17 0004 04 & REC17 0002.04Related documentApplication case desk ↗
About this file
- File size
- 10.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file