                                                                                                                                                                        EXTERIOR FINISHES LEGEND
                                                                                                                    8m Above Existing Ground Line            CODE                  DESCRIPTION
                                                                                                                                                             ECL-01 Hardies Scyon Linea 180mm, painted
                 Colorbond Custom Orb roof sheeting                                                                                                          ECL-02 Block with 10mm[nom] smooth cement
                 on trusses at 900crs                                                                               ERO-02                                          render finish + painted
                                                                                                                                                             ECL-03 Hardietex FC with smooth render finish +
          Roof                                                                                                                                                      painted
          8430                                                                                                                                                EFL-01 Metal roof flashing to match roof
                 Colorbond fascia and gutter, to                                                                                                             EJO-01 Aluminium joinery, powder coated
                 selection, fixed to manuf's specs                                                                                                           EJO-02 Aluminium joinery, powder coated
2600




                                                             EJO-03                                                 ECL -01                                  EJO-03 Aluminium joinery, powder coated
                 Hardies Scyon Linea 180mm FC                                                                                                                ERO-02 Colorbond Custom Orb roof sheeting
                 cladding fixed to manuf's specs                                                                                                              ESS-01 316 Marine Grade Stainless Steel
                                                                                                                    Colorbond Custom Orb roof sheeting
          First Floor                                                                                               on trusses at 900crs                     ETP-01 HWD timber post, painted
          5830

                                                             EFA-01
                 1200mm high frameless                       ETP-01
                 glass pool fence and gate
2750




                 in accordance with QBCC,
                 QDC MP3.4 & A.S.1926


          Ground Floor
          2700
          Flood Level
          2400
                                                                                                                     Existing Ground Line




                                                                      HOUSE 2 SOUTH ELEVATION
                                                             3        Scale: 1 : 100




                                                                                                                                                                                        -

                                                                                                                                                             NOOSA COUNCIL
                     Colorbond Custom Orb roof sheeting
                     on trusses at 900crs

       Roof                                                                                                                                                  APPROVED PLAN
       8430
                     Privacy screen with 25% max visibilty                                                                                                    MCU17/0004.01,
                     up to 1500mm min above FFL, refer
                                                                                                        ECL -01                                          OPW17/0005.01 & REC17/0002
2600




                     detail
                                                                                                                                                                4 MAR 2019
                     Hardies Scyon Linea 180mm FC                                                         ECL -02
                     cladding fixed to manuf's specs
       First Floor
       5830                                                                                                                                                                                                                              SITE
                                                                                                                                                                                            46-48 ELIZABETH STREET
                                                                                                                    1200mm high frameless glass pool                                        NOOSAVILLE, QLD 4566
                     140x140 Dressed HWD timber posts,                                                                                                                                                                             PROJECT
                                                                                                                    fence and gate in accordance with
                     paint finish to selection                                                                                                                                  TOWNHOUSE DEVELOPMENT
                                                                                                                    QBCC, QDC MP3.4 & A.S.1926
2750




                                                                                                                                                                                                                                      CLIENT
                                                                                                                                                                                                 46 ELIZABETH Pty Ltd
                                                                                                                                                                                                                           DRAWING TITLE
                                                                                                                     ECL -02                                                                   HOUSE 2 ELEVATIONS
       Ground Floor
       2700                                                                                                                                                                                 DESIGNED                                  SCALE
                                                                                                                                                                                             B.D.H.                               1 : 100
                                                                                                                                                                                            CHECKED                         STAGE - ISSUE
                                                                                                                                                                                             B.D.H.                               BA - C
                                                                                                                                                                                              DRAWN                                    DATE
                                                                                                                                                                                                    MJ                   26.02.2019
                                                                                                                                                                                       PROJECT No.                                PAGE No.
                                                                      HOUSE 2 WEST ELEVATION                                                                                                 18070                     D20 OF 84
                                                             4        Scale: 1 : 100                                                                                0            1              2              3              4          5m


                                                                                                                                                                    1: 100             1 3 0 0   1 3 3    9 1 7
                                                                                                                                                                                       [email protected]


                                                                                                PRELIMINARY - NOT FOR CONSTRUCTION                                                                                 Q.B.C.C. 1029724
                                                                                                                                                                                                                26/02/2019 11: 23: 52 AM

Used in these records

About this file

File size
10.8 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Compiled Approved Plans MCU17 0004 04 & REC17 0002.04.pdf · 10.8 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.