Council archive · source document
Appendix 1 Gateway Drive Code Assessment Ver1 · MCU15/0031
Attached to the e-mail MCU15/0031 & OPW15/0057 Development Application.
MCU to establish Entertainment and Dining Business (Type 1 Food and Beverage)
MCU to establish Industrial Business – Type 2 Production, Alteration, Repackaging and Repairing
2/18 Duke St Sunshine Beach
Lot 11Gateway Drive, Noosaville
Acceptable solutions
Specific Outcomes Proposal Outcomes
(if self-assessable)
O5 The provision of landscaping is to a S5.1 Landscaping provided which allows Complies - Refer Appendix 3
satisfactory standard ensuring that it does not adequate visibility for casual surveillance of Proposal Plans and Appendix 5
lead to opportunities for concealment and public and semi-public spaces, including Landscaping Plans for details.
possible assault sites. entrances and exits to sites and buildings, by:
a) planting trees which have clean trunks to
a height of at least 1.8m; and
b) appropriately spacing shrubs at 1.2m
horizontal centres, with a maximum
height of 0.75m, to avoid clumping and to
retain sightlines.
S6.1 Street trees and trees in carparking areas
achieve a maximum of 900mm clear trunk Complies - Refer Appendix 3
height for a 2.0m high tree at planting and are Proposal Plans and Appendix 5
O6 Street trees and plantings in towns and able to attain a clear trunk height of 1900mm Landscaping Plans for details.
villages, carparks and other areas where on maturity;
potential conflicts with vehicles and pedestrians
are evident, are planted so as to maximise AND
vehicle and pedestrian safety. S6.2 All scrub planting to be a maximum Complies - Refer Appendix 3
height of 700mm from the road pavement (not Proposal Plans and Appendix 5
top of kerb). Landscaping Plans for details.
Services and utilities
O7 All landscaping works maintain adequate S7.1 Plant species used in landscaping N/A
safe distance from services and utilities including adjacent to substations, or adjacent to or on
substations, overhead powerlines, power poles e l e c t r i c i t y transmission line easements,
and transformers, street lamps, stormwater are less than 4m high at maturity and do not
catchment pits, and underground services and encroach within 3m of a substation boundary;
utilities. OR
S7.2 For trees higher than 4m, trees are
Figure 14-17 planted at a d i s t a n c e from any part of an
electricity transmission line at least equal to
the expected height of the tree at maturity
(see Figure 14-17);
AND
S7.3 For power lines that connect to a
premises, the height of plant species at
maturity provides for a 2m clearance below
the power line; (see Figure 14-18)
AND
S7.4 Trees and large scrubs are located a
Figure 14-18 minimum of—
a) 5m from electricity poles and pillars;
b) 4m from street lamps;
c) 2m from stormwater catchment pits; and
Page 19 of 22
PT010115 VER 1.1 060215
See the original
The page text is free to read. Viewing or downloading an original file needs an account.