Council archive · source document
Appendix 1 Gateway Drive Code Assessment Ver1 · MCU15/0031
Attached to the e-mail MCU15/0031 & OPW15/0057 Development Application.
MCU to establish Entertainment and Dining Business (Type 1 Food and Beverage)
MCU to establish Industrial Business – Type 2 Production, Alteration, Repackaging and Repairing
2/18 Duke St Sunshine Beach
Lot 11Gateway Drive, Noosaville
Acceptable solutions
Specific Outcomes Proposal Outcomes
(if self-assessable)
d) 2m from underground services and
utilities;
e) AND
S7.5 Plants are located to enable
tradespersons to access, view and inspect
service meters, such as water and electricity
meters;
AND
S7.6 Root barriers are installed around trees
that are located within 3m of any
infrastructures or that have potentially
invasive roots.
14.136 Specific Requirements for Business Uses
Industrial Business
O20 Landscaping within industrial developments No solution provided Complies - Refer Appendix 3
is designed to— Figure 14-25 Appropriate species at correct Proposal Plans and Appendix
a) maximise retention of existing vegetation; density and height effectively screen bulky 5 Landscaping Plans for
b) provide planting in mulched areas at industrial buildings details.
entrances, along boundaries and around
car parking and site facilities to provide
screening and shading;
c) lessen the impact of building bulk though
the planting of vegetation that is in scale
with the building, and by using mounding
where appropriate (see Figure 14-25); and
d) provide outdoor areas for staff.
14.139 Carparking areas
Off street carparks
28
O28 Landscaping of carparking areas is Complies - Refer Appendix 3
S28.1 One advanced canopy tree (a
designed to— Proposal Plans and Appendix 5
minimum of 100 litres pot size) is provided—
a) reduced the visual impact of the Landscaping Plans for details.
a) in towns and villages, shopping centres
development;
or commercial areas— for every 4
b) provide for advanced canopy trees to
carparking spaces; or
shade vehicles and to reduce reflected
radiation; b) otherwise—for every 6 carparking
c) ensure canopy trees are protected from spaces;
vehicle damage by providing adequate AND
sized garden beds; 2
d) maximise opportunities for infiltration of S28.2 A minimum area of 5m is provided
rainwater on-site; and around each canopy tree, which is mulched
e) minimise contaminated runoff entering the and treated;
stormwater system and watercourse. AND
S28.3 Plants are grouped in mulched beds
rather than using individual, evenly spaced
Page 20 of 22
PT010115 VER 1.1 060215
See the original
The page text is free to read. Viewing or downloading an original file needs an account.