Council archive · source document
Council Drawings - Unit 14, 30 Hasting St · 51983.3225.24
KEY SITE REQUIREMENTS NOTES
CSD CAVITY SLIDING DOOR MFR METAL FLAT ROOF SD SMOKE DETECTOR · ALL TOILET DOORS TO HAVE LIFT OF HINGES · LIVABLE HOUSING DESIGN STANDARD 2022 COMPLIANT BATHROOM TO INCLUDE MINIMUM 820mm CLEAR OPENING, HOBLESS / STEP FREE ENTRY,
SITE 124.60m2 · RL'S ARE ASSUMED ONLY AND SHALL BE VERIFIED BY BUILDER PRIOR TO NO LIP GREATER THEN 5MM. REFER TO figure A4(3) ON QDC MP4.5 FOR FURTHER DETAILS. ENSURE RE-INFORCING IS DONE AS PER PART 6 OF
D DOOR MPR METAL PITCHED ROOF HT HOSE TAP COMMENCEMENT OF SITE WORKS LIVABLE HOUSING CODE.
· ALL BASINS & BATHS TO HAVE OVERFLOWS · ALL RELEVANT PAHTS & FLUSH TRANSITIONS AS REQUIRED BY NCC LIVABLE HOUSING CODE TO BE INSTATED TO CODE BY BUILDER. VOS WITH
GD GLASS DOOR FR CONCRETE FLAT ROOF G GAS POINT SITE COVER: ALLOWED: 73.55m2
· PDR TO MEET REQUIREMENTS STATED IN THE 'LIVABLE HOUSING DESIGN STANDARD DESIGNER & CERTIFIER IF REQUIRED.
ACTUAL: 73.50m2
W WINDOW DP DOWN PIPE NGL NATURAL GROUND LEVEL 2022' · DOWN PIPES & ROOF DRAINAGE LOCATIONS ARE SUGGESTED ONLY AND BUILDER SHOULD ENSURE ADEQUATE STORMWATER FALL & DRAINAGE
· PDR TO HAVE MECHANICAL VENTILATION AS REQUIRED
FG FLOOR GULLY RH RAINHEAD FGL FINISHED GROUND LEVEL GFA: ALLOWED: 216.8m2 · ALL BASINS & BATHS TO HAVE OVERFLOWS · DRAINAGE SHOULD BE CONCEALED WITHIN SLAB WHERE NOTED.
ACTUAL: 194.48m2 · FOR ALL LANDSCAPING REFER TO LANDSCAPING CONSULTANTS DETAILED DRAWINGS · FOR ALL WET AREAS, SET DOWN FLOOR CONSTRUCTION TO PROVIDE TILED FLOOR FLUSH WITH ADJOINING FFL, FALL TO WASTE, DROP SHOWER
PD PLUMBING DUCT FALL DIRECTION RL FINISHED LEVEL
LOT 18
N
LOT 13
3.6
900
400 113 6
°50
'
ALUMINUM ENTRY GATE
LINE OF FENCING
LEVEL OVER
1
3.
5'
4.3
DP X2
113 87
23°
PEDESTRIAN
PD °50 GATE
'
G
0 G
GLASS BALLUSTRADE IN 2 .50
ACCORDANCE WITH AS1288
RL HT
A 9.5
700
90°0' LINE OF PELMET
180°0'
ABOVE EXISTING
DP X2
2.3
VEGETATION
3000 FLOOR TO FLOOR
17 [email protected]
HT W4
GARAGE SIDE GATE
00°0'
PD STEP FREE RAMPING
PD
STAIRS
2.6
UP ENTRY INTO GARAGE
CONCRETE
7 6 5 4 3 2 1
LIFT 2600 CEILING
EASY LIVING
Y
8 STORAGE ADVANTAGE V2
WA
LIFT
BELOW LINE OF
EXISTING STAIRS
VEGETATION
LIFT MECHANICS
GD LEVEL OVER
RS
IVE
LINE OF
VE
LEVEL ABOVE STEP FREE RAMPING
900
PA
CS ENTRY INTO GARAGE
50
D
DR
4 .5
133
2
RL
CLOTHES LINE
LAUNDRY 168
0 LOT 16
TIMBER
TUB
D2 2600 CEILING SLIDING
CABINETRY
DOORS
WM & SD
°5'
203 5
DRY
8.4
ALUMINUM
W3 STACK
ENTRY ENTRY GATE
W1
16. HT
LINEN
087 STEPPERS
293 ENTRY
EXISTING
°50 TERRACE
BOUNDARY
EXISTING ' FENCE
LANDSCAPING OUTDOOR LINE OF 50 D1
0
.50
SHOWER PAD LEVEL OVER
W2 2
5
RL
118
STEPPERS
STEPPERS
NOO LINE OF
EXISTING
LANDSCAPING
SA LEVEL OVER
PAR A
ADE
GROUND FLOOR PLAN
PAUL CLOUT DESIGN GENERAL NOTES:
Suite 3, 44 MARY STREET, NOOSAVILLE
CLIENT NAME: Ptasznik, Rainer & Kate
Use written dimensions only. DO NOT scale drawings. Contractors to verify all
PO BOX 152, NOOSAVILLE, QLD 4566. dimensions on site prior to commencing works. Site location is Category W41 SITE ADDRESS: Unit 14-30, Hasting St
BSA LICENCE: 1066417 or to engineer's requirements. These drawings are to be read in conjunction SCALE: 1:100 ON A3
with engineer's design and details, the accompanying building specification and DRAWING TITLE: GROUND PLAN
schedule of finishes. If in doubt, please request clarification. DO NOT ASSUME. DRAWING DATE: 06/05/2025
PH: (07) 5440 5388 STAGE: COUNCIL DRAWINGS DRAWING No. 2.0
[email protected] @COPYRIGHT PAUL CLOUT DESIGN PTY LTD.
www.paulclout.com
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Council Drawings - Unit 14, 30 Hasting St.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.