Council Drawings - Unit 14, 30 Hasting St · 51983.3225.24
KEY SITE REQUIREMENTS NOTES
CSD CAVITY SLIDING DOOR MFR METAL FLAT ROOF SD SMOKE DETECTOR · ALL TOILET DOORS TO HAVE LIFT OF HINGES · LIVABLE HOUSING DESIGN STANDARD 2022 COMPLIANT BATHROOM TO INCLUDE MINIMUM 820mm CLEAR OPENING, HOBLESS / STEP FREE ENTRY,
SITE 124.60m2 · RL'S ARE ASSUMED ONLY AND SHALL BE VERIFIED BY BUILDER PRIOR TO NO LIP GREATER THEN 5MM. REFER TO figure A4(3) ON QDC MP4.5 FOR FURTHER DETAILS. ENSURE RE-INFORCING IS DONE AS PER PART 6 OF
D DOOR MPR METAL PITCHED ROOF HT HOSE TAP COMMENCEMENT OF SITE WORKS LIVABLE HOUSING CODE.
· ALL BASINS & BATHS TO HAVE OVERFLOWS · ALL RELEVANT PAHTS & FLUSH TRANSITIONS AS REQUIRED BY NCC LIVABLE HOUSING CODE TO BE INSTATED TO CODE BY BUILDER. VOS WITH
GD GLASS DOOR FR CONCRETE FLAT ROOF G GAS POINT SITE COVER: ALLOWED: 73.55m2
· PDR TO MEET REQUIREMENTS STATED IN THE 'LIVABLE HOUSING DESIGN STANDARD DESIGNER & CERTIFIER IF REQUIRED.
ACTUAL: 73.50m2
W WINDOW DP DOWN PIPE NGL NATURAL GROUND LEVEL 2022' · DOWN PIPES & ROOF DRAINAGE LOCATIONS ARE SUGGESTED ONLY AND BUILDER SHOULD ENSURE ADEQUATE STORMWATER FALL & DRAINAGE
· PDR TO HAVE MECHANICAL VENTILATION AS REQUIRED
FG FLOOR GULLY RH RAINHEAD FGL FINISHED GROUND LEVEL GFA: ALLOWED: 216.8m2 · ALL BASINS & BATHS TO HAVE OVERFLOWS · DRAINAGE SHOULD BE CONCEALED WITHIN SLAB WHERE NOTED.
ACTUAL: 194.48m2 · FOR ALL LANDSCAPING REFER TO LANDSCAPING CONSULTANTS DETAILED DRAWINGS · FOR ALL WET AREAS, SET DOWN FLOOR CONSTRUCTION TO PROVIDE TILED FLOOR FLUSH WITH ADJOINING FFL, FALL TO WASTE, DROP SHOWER
PD PLUMBING DUCT FALL DIRECTION RL FINISHED LEVEL
N
WINDOW HOOD 3.6
800 113 6
°50
'
W10
1
FG WINDOW HOOD
3.
5'
4.3
113 87
DP X2
23°
SHOWER
W11 °50'
OW
PD
ENS
EL
800
FB
OO
TILES
TR
N
GLASS BALLUSTRADE IN 2400 CEILING
R
FLA
TE
ACCORDANCE WITH AS1288
50 BED 2
CIS
A 9.5
.5
L5
TIMBER
700
90°0' LINE OF PELMET
R
180°0'
ABOVE
2600 CEILING
DP X2
2.3
820
W9 CS
D
820 50 FG
00°0'
PD D SD .5
L5
2.6
LINE OF PELMET PRIVACY
UP
50 ABOVE SCREENS
STAIRS 5.5 LIFT SD R
W5
RL
5 4 3 2 1
D
820
11 VOID
12
13
14 SD
15 ROBE
R N
16
700
TE
17
GALLERY
CIS
DN
TIMBER
ER
3000 FLOOR TO FLOOR
2600 CEILING ENS ROBE
BED 3
TILES FG
NT
17 [email protected]
TIMBER
D
2400 CEILING
CS
A
LINEN 2600 CEILING
4
800
W8
PL
133
FG
LINE OF DROPPED
SHOWER
0
LINE OF PELMET CEILING
50
150
ABOVE FG
5.5
°5'
ROBE
170
203 5
8.4
PLANTER
W7 L 0
16. R LINE OF PELMET
ABOVE
087
700
PRIVACY
PRIVACY
293 SCREENS
D3 SCREENS
°50
' TERRACE
FG 0
500
.50
TILES
5 HT W6
FG
RL
700
TERRACE GLASS BALLUSTRADE
IN ACCORDANCE WITH AS1288
A
LEVEL 1 PLAN
PAUL CLOUT DESIGN GENERAL NOTES:
Suite 3, 44 MARY STREET, NOOSAVILLE
CLIENT NAME: Ptasznik, Rainer & Kate
Use written dimensions only. DO NOT scale drawings. Contractors to verify all
PO BOX 152, NOOSAVILLE, QLD 4566. dimensions on site prior to commencing works. Site location is Category W41 SITE ADDRESS: Unit 14-30, Hasting St
BSA LICENCE: 1066417 or to engineer's requirements. These drawings are to be read in conjunction SCALE: 1:100 ON A3
with engineer's design and details, the accompanying building specification and DRAWING TITLE: LEVEL 1 PLAN
schedule of finishes. If in doubt, please request clarification. DO NOT ASSUME. DRAWING DATE: 06/05/2025
PH: (07) 5440 5388 STAGE: COUNCIL DRAWINGS DRAWING No. 3.0
[email protected] @COPYRIGHT PAUL CLOUT DESIGN PTY LTD.
www.paulclout.com
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Council Drawings - Unit 14, 30 Hasting St.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.