Noosa on Weyba
Bushfire Assessment Report



Performance Criteria                 Acceptable Measures                            Noosa on Weyba Response
and emergency personnel, on          (b) if a) is not possible, a perimeter track
the event of an emergency,           on a minimum cleared width of 6 metres
including alternative safe access    within the development site to adjacent
routes should access in one          bushland which has a grade not greater
direction be blocked in the          than 12.5%;
event of a fire; and                  AND
(c) providing for the separation     A3.2 The road design is capable of
of developed areas and adjacent      providing access for fire fighting and other
bushland.                            emergency vehicles by incorporating
                                     through roads only and road grades not
                                     exceeding 12.5%.
                                      AND
                                     A3.3 Any perimeter track:
                                     • incorporates access points at either end,
                                     a vehicle passing bay every 200 metres
                                     and a vehicle turnaround every 400 metres;
                                     • has a formed width and gradient, and
                                     erosion control devices to local government
                                     standards;
                                     • is either dedicated to Council, or within
                                     an access easement that is granted in
                                     favour of Council and Queensland Fire and
                                     Rescue Service.

Element 3: Siting, Building Design and Construction 3
P1 Buildings and structures are  A1.1 Buildings and structures are sited in         Complies – As detailed in Section 4
sited to minimise potential      the area of lowest bushfire hazard.                the Noosa on Weyba Concept Master
bushfire hazard and associated   AND                                                Plan makes provision for measures
clearing of remnant vegetation.  A1.2 Buildings and structures are located          that are consistent with A1.1 and
                                 away from the most likely direction of a fire      A1.2.
                                 front, or on a flat site at the base of the
                                 slope.                                             The Noosa on Weyba Concept Master
                                 AND                                                Plan would not require the clearing of
                                 A1.3 No clearing of remnant vegetation             remnant vegetation identified on
                                 identified on Regulatory Map 1.1 Nature            Regulatory Map 1.1 Nature
                                 Conservation Management Areas Special              Conservation Management Areas
                                 Management Area is required.                       Special Management Area for bushfire
                                 AND                                                hazard mitigation purposes and is
                                 A1.4 On properties where boundary fences           thereby consistent with A1.3.
                                 abutting native bushland areas,
                                 construction of timber paling fencing should       The Noosa on Weyba Concept Plan
                                 not be permitted. The construction of              does not proposed the construction of
                                 colourbond steel fences is permitted.              timber paling fencing along
                                                                                    boundaries adjacent to retained (or re-
                                                                                    established) bushland habitats and
                                                                                    conditions of approval to that effect
                                                                                    could be imposes. Therefore the
                                                                                    Noosa on Weyba proposal is
                                                                                    consistent with A1.4.
Element 4: Water Supply
P1 The development proposed          A1.1 Each dwelling unit on the site with a     Complies –
provides an adequate water           gross floor area greater than 50m² has a
supply for fire fighting purposes    reliable reticulated water supply that has a   As detailed in Section 4.2, the Noosa
and the water supply provided        minimum pressure and flow of 10 litres a       on Weyba proposal complies with
for fire fighting purposes must be   second at 200kPa at all times.                 A1.1 and compliance with A1.3 – A1.9
safely located and freely            OR                                             can be conditioned
accessible for fire fighting         A1.2 Each dwelling unit on the site has an
purposes at all times. The water     on-site water supply volume of not less
supply must be reliable, and         than 20,000 litres available for the
have sufficient flow and pressure    purposes of fire fighting.
requirements for fire fighting       The water supply can be either:
purposes at all times.               (a) a separate tank; or
                                     (b) a reserve section in the bottom part of
                                     the main water supply tank; or
                                     (c) a swimming pool installed immediately
                                     upon construction of the development.


Northbrook Corporation Pty Ltd                          Version 2                                           11 October 2013
Bushfire Assessment Report v2.docx                Commercial in Confidence                                         Page 21

Used in these records

About this file

File size
11.7 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment 9- Amended Bushfire Assessment Report MCU12_0208.pdf · 11.7 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.