Original source · versioned page text
Approved Plans - MCU20-0072
Plans and drawings: the text below has words only, no drawings.
Very large file (15.3 MB): may take a few minutes to open.
1 2 3 4 5 6 7 8 9 10 -
APPROVED PLANS
30850
MCU20/0072
NOOSA COUNCIL
19 AUGUST 2021
-
?
A A
Proposed New Building
5°
9600
9600
12000
12000
RF01
B B
2400
2400
RF01
5°
C C
PL01
3400 3400 3450 3400 3450 3400 3450 3450 3450
I Moved ramp, Added deck, stairs & windows 15.07.2020 CB
H Moved Staff Room 30.06.2020 CB
Module 1 Module 2 Module 3 Module 4 Module 5 Module 6 Module 7 Module 8 Module 9
G Bigger Breakout Room 2 29.06.2020 CB
F Adjusted Building Location and added RL's, Moved Stairs and 26.07.2019 JP
Ramp
E Resizing of Buildings and Layouts. Relocated Office Moved 19.07.2019 JP
1 2 3 4 5 6 7 8 9 10 D For Client Approval 31.08.2018 IC
Iss. Description Date By
1. Ground Floor Roof FOR APPROVAL
1 : 100
General Notes & Disclaimers
COPYRIGHT AUSCO MODULAR PTY LTD. THIS DOCUMENT MAY NOT BE
• Wall/Ceiling/Roof frames built to Ausco REPRODUCED OR HAVE ITS CONTENTS DIVULGED WITHOUT WRITTEN
Backbone framing design standards. Title
AUTHORITY.
• Building chassis designed to Ausco
Standard Chassis drawings.
• All work must be done in accordance with
Roof Plan (MQB)
the relevant Australian/New Zealand
Standard(s) and the National Construction
Code.
• Furniture, plumbing, & electrical
representations are indicative. Appearance Project
may vary depending on supplier. 30.85x12m Learning Centre-
• Loose items to be packed for transport.
• Site, stairs, ramp and building skirting SG (B190)
Client
indicative only. Size, fall and location to suit
site conditions. Constructed to comply with Good Shepard Lutheran
AS1428.1.
Manufactured to Wind Speed: B190 College
Manufactured in: MQB
Intended Location: Noosaville, QLD
Client Approval Drawn By Drawn Date Scale
Frame
Manufacturing - Roof
Sheet
Drawings - Architectural
Content Rev Client: Good Shepard Lutheran College IC MAR 18 1 : 100 A2
Checked By Check Date
Tag Frame Crs. Cladding Lining Insulation
A-000 Schedules - Building Shell I
Approved by: DIMENSIONS ARE IN MM
AAD MAR 18
15/07/2020 7:00:57 PM
A-001 Site Plan I
RF01 Engineered steel 1100 Custom Orb (Deep - R1.8 Glass Wool DO NOT SCALE
A-100 Ground Floor Plan I Company: Project No. Order No.
frame purlins, Ocean) Foil
75mm, "Lipped C"
section
A-101
A-200
Roof Plan
Elevations
I
I Date (dd-mm-yyyy): 0240100047 -
A-300 Ground Floor RCP I Drawing No. Sheet Issue
- A-101 I
Signature:
A-500 Section & Details I
Designed by: Brisbane
Document Set ID: 21594200
21213117
21260700
Version: 1, Version Date: 25/08/2021
05/08/2020
14/10/2020
See the original