Original source · versioned page text
Approved Plans - MCU20-0072
Plans and drawings: the text below has words only, no drawings.
Very large file (15.3 MB): may take a few minutes to open.
General Notes & Disclaimers
1 2 3 4 5 6 7 8 9 10 • Wall/Ceiling/Roof frames built to Ausco
3400 3400 3450 3400 3450 3400 3450 3450 3450 Backbone framing design standards.
• Building chassis designed to Ausco
Standard Chassis drawings.
• All work must be done in accordance with
the relevant Australian/New Zealand
Standard(s) and the National Construction
Ceiling Pitch Point Code.
W4 W4 W4 W4 • Furniture, plumbing, & electrical
2705 representations are indicative. Appearance
may vary depending on supplier.
W01 W01 W01 W02 W02 W01
Deck Ceiling • Loose items to be packed for transport.
D02 D02 D02 2405 • Site, stairs, ramp and building skirting
indicative only. Size, fall and location to suit
0 0 Ground Floor site conditions. Constructed to comply with
AS1428.1.
600
-773 0 Manufactured to Wind Speed: B190
Datum Manufactured in: MQB
-1755
Intended Location: Noosaville, QLD
-600
Client Approval
Client: Good Shepard Lutheran College
2. Project South
Approved by:
A-200 1 : 120
Company:
Date (dd-mm-yyyy):
A B C C B A
9600 2400 Signature:
2400 9600
Drawings - Architectural
Ceiling Pitch Point Ceiling Pitch Point Sheet Content Rev
2705 2705 A-000 Schedules - Building Shell I
A-001 Site Plan I
Deck Ceiling Deck Ceiling
A-100 Ground Floor Plan I
2405 2405 A-101 Roof Plan I
A-200 Elevations I
A-300 Ground Floor RCP I
A-500 Section & Details I
Ground Floor Ground Floor
0 0
Datum Datum
-600 -600
5. Project West 3. Project East
A-200 1 : 120 A-200 1 : 120
I Moved ramp, Added deck, stairs & windows 15.07.2020 CB
H Moved Staff Room 30.06.2020 CB
10 9 8 7 6 5 4 3 2 1 G Bigger Breakout Room 2 29.06.2020 CB
3450 3450 3450 3400 3450 3400 3450 3400 3400 F Adjusted Building Location and added RL's, Moved Stairs and 26.07.2019 JP
Ramp
E Resizing of Buildings and Layouts. Relocated Office Moved 19.07.2019 JP
D For Client Approval 31.08.2018 IC
Existing Admin Building
Iss. Description Date By
Ceiling Pitch Point FOR APPROVAL
2705
Deck Ceiling W01 W01 W01 W01 W01 W02 W02 W01
2405 COPYRIGHT AUSCO MODULAR PTY LTD. THIS DOCUMENT MAY NOT BE
REPRODUCED OR HAVE ITS CONTENTS DIVULGED WITHOUT WRITTEN
AUTHORITY.
Ground Floor 0 0 Title
0
-1261
Elevations (MQB)
Datum
-600 -2078
Ground Level as per suveryors drawing
A-200 Project
4. Project North 30.85x12m Learning Centre-
A-200 1 : 120
GL-FFL +2078 4 GL-FFL +1261 SG (B190)
Client
Good Shepard Lutheran
A-200 5 3 A-200
College
GL-FFL +1755 2 GL-FFL +773
Drawn By Drawn Date Scale
-
Existing Admin Building
DN A-200
IC MAR 18
As
indicated A2
APPROVED PLANS Checked By Check Date
DIMENSIONS ARE IN MM
AAD MAR 18
MCU20/0072
15/07/2020 7:01:04 PM
DO NOT SCALE
NOOSA COUNCIL Project No. Order No.
19 AUGUST 2021 0240100047 -
- Drawing No. Sheet Issue
- A-200 I
Designed by: Brisbane
Document Set ID: 21594200
21213117
21260700
Version: 1, Version Date: 25/08/2021
05/08/2020
14/10/2020
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.